Back to Search
Start Over
2T superconducting detector solenoid for the PANDA target spectrometer
- Source :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 585:182-200
- Publication Year :
- 2008
- Publisher :
- Elsevier BV, 2008.
-
Abstract
- This paper describes the JINR design of the large 2 T superconducting solenoid for the target spectrometer of the PANDA experiment at HESR (FAIR, GSI, Darmstadt, Germany). The solenoid coil has an inner radius of 1.08 m and a length of 2.90 m. This solenoid is non-centrally split providing a warm bore of 100 mm in diameter through the coil to accommodate sufficient space for the internal target installations. Maximally stored energy in the windings is 22.3 MJ. All tracking and calorimetric detectors surrounding the target point, with exception of a forward cone of 5 ∘ opening, are placed inside the lqHe-cryostat. The main features of the design and technique are as follows: a copper stabilizer and soldering technique for the superconducting cable; a stainless steel cryostat; winding technique over a mandrel; coreless type of the coil; low operational current. The details of the PANDA solenoid design including the magnetic field and stress–strain calculations are covered.
- Subjects :
- Physics
Cryostat
Nuclear and High Energy Physics
Spectrometer
Physics::Instrumentation and Detectors
business.industry
Detector
Solenoid
Tracking (particle physics)
Magnetic field
Mandrel
Nuclear magnetic resonance
Optics
Electromagnetic coil
Physics::Accelerator Physics
Nuclear Experiment
business
Instrumentation
Subjects
Details
- ISSN :
- 01689002
- Volume :
- 585
- Database :
- OpenAIRE
- Journal :
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Accession number :
- edsair.doi...........f8a6b43555d686364fd4b1936bc9f933
- Full Text :
- https://doi.org/10.1016/j.nima.2007.11.021