Back to Search Start Over

Hemodynamic heterogeneity of inadequate cardiac output increase identified by 2-dimensional volumetric exercise echocardiography: slow, stiff or weak heart?

Authors :
Tamara Kovacevic-Preradovic
Ana Djordjevic-Dikic
T. Bombardini
Miodrag Ostojic
Antonello D'Andrea
Karina Wierzbowska-Drabik
Lauro Cortigiani
Eugenio Picano
C Borguezan Daros
Nadezhda Zhuravskaya
Jarosław D. Kasprzak
Biljana Beleslin
Quirino Ciampi
Angela Zagatina
J L De Castro E Silva Pretto
Source :
European Heart Journal. 41
Publication Year :
2020
Publisher :
Oxford University Press (OUP), 2020.

Abstract

Background Two-dimensional (2-D) volumetric exercise stress echocardiography (ESE) provides an integrated view of preload reserve through end-diastolic volume (EDV) and left ventricular contractile reserve (LVCR) through end-systolic volume (ESV) changes. Purpose To assess the dependence of stroke volume (SV) and cardiac output (CO) upon LVCR EDV changes and heart rate (HR) during ESE. Methods We prospectively performed semi-supine bicycle or treadmill ESE in 1,344 patients (age 59.8±11.4 years; 550 female; ejection fraction = 62.5±8%) referred for known or suspected coronary artery disease in 20 quality controlled laboratories of 16 countries from 2016 to 2019. SV was calculated at rest and peak stress from raw measurement of LV EDV and ESV by biplane Simpson rule, 2-D echo. LVCR was the stress-rest ratio of force (systolic blood pressure by cuff sphygmomanometer/ESV, abnormal values Results By selection, all patients had negative SE by wall motion criteria. Of the 1,344 patients included in the study, 448 belonged to the lowest tertile of CO increase. Of them 326 (73%) achieved HR reserve Conclusion Patients with normal CO reserve during exercise usually have a fast, compliant and strong heart. Abnormal CO reserve is associated with heterogeneous hemodynamic responses, with slow, stiff and/or weak hearts. The clarification of underlying hemodynamic heterogeneity is the prerequisite for a personalized treatment, and can be easily extracted from a standard 2-D volumetric SE. Hearts with normal CO are all alike; every heart with abnormal CO is abnormal in its own way. CO % changes in subsets (*p Funding Acknowledgement Type of funding source: None

Details

ISSN :
15229645 and 0195668X
Volume :
41
Database :
OpenAIRE
Journal :
European Heart Journal
Accession number :
edsair.doi...........fdfdefaaf67e5000ef30675ba6073f21
Full Text :
https://doi.org/10.1093/ehjci/ehaa946.0037