Back to Search Start Over

Development of an accelerated test for pitting corrosion of CUSTOM 450 by rDHM

Authors :
Ramin Khamedi
Yousef Mollapour
Hassan Shayani-Jam
Esmaeil Poursaeidi
Omid Pedram
Source :
International Journal of Materials Research. 112:600-609
Publication Year :
2021
Publisher :
Walter de Gruyter GmbH, 2021.

Abstract

A key application of CUSTOM 450 alloy is in the construction of gas turbine compressor blades. The study of pitting corrosion can prevent the failure of many gas turbine compressor blades. In this study, a reflective digital holography microscopy method was employed to investigate the growth of pitting corrosion in depth. To this end, a constant potential of 350 mVSCE in a 3.5 wt.% NaCl solution was applied to the specimen. The generated pits were simulated in three dimensions, and it was indicated that pitting corrosion rate was decreased as time passed. Comparing the obtained experimental data with the data gathered from the real industrial environment surrounding a compressor installation, an accelerated test was proposed. By the proposed accelerated test, it is possible to produce a pit similar to the one that will be initiated and propagated at any time in the future in real conditions.

Details

ISSN :
21958556 and 18625282
Volume :
112
Database :
OpenAIRE
Journal :
International Journal of Materials Research
Accession number :
edsair.doi...........ff10d7c4d70b1f2e4fd75838bb0b84c8
Full Text :
https://doi.org/10.1515/ijmr-2020-7998