Back to Search Start Over

Type 2 diabetes mellitus is associated with faster degeneration of bioprosthetic valve: results from a propensity score-matched Italian multicenter study

Authors :
Roberto, Lorusso
Sandro, Gelsomino
Fabiana, Lucà
Giuseppe, De Cicco
Giuseppe, Billè
Rocco, Carella
Emmanuel, Villa
Emanuel, Villa
Gianni, Troise
Mario, Viganò
Carlo, Banfi
Carmine, Gazzaruso
Pier, Gagliardotto
Lorenzo, Menicanti
Francesco, Formica
Giovanni, Paolini
Stefano, Benussi
Ottavio, Alfieri
Matteo, Pastore
Sandro, Ferrarese
Giovanni, Mariscalco
Germano, Di Credico
Cristian, Leva
Claudio, Russo
Aldo, Cannata
Roberto, Trevisan
Ugolino, Livi
Roberto, Scrofani
Carlo, Antona
Andrea, Sala
Gian Franco, Gensini
Jos, Maessen
Andrea, Giustina
Lorusso, R
Gelsomino, S
Lucà, F
De Cicco, G
Billè, G
Carella, R
Villa, E
Troise, G
Viganò, M
Banfi, C
Gazzaruso, C
Gagliardotto, P
Menicanti, L
Formica, F
Paolini, G
Benussi, S
Alfieri, O
Pastore, M
Ferrarese, S
Mariscalco, G
Di Credico, G
Leva, C
Russo, C
Cannata, A
Trevisan, R
Livi, U
Scrofani, R
Antona, C
Sala, A
Gensini, G
Maessen, J
Giustina, A
Luca', F
Bille', G
Vigano', M
Alfieri, Ottavio
Gensini, Gf
Giustina, Andrea
RS: CARIM - R2.12 - Surgical intervention
CTC
MUMC+: MA Cardiothoracale Chirurgie (3)
Source :
Circulation, 125(4), 604-614. LIPPINCOTT WILLIAMS & WILKINS
Publication Year :
2011

Abstract

Background— The present study was aimed at determining the impact of type 2 diabetes mellitus (DM) on postoperative bioprosthetic structural valve degeneration. Methods and Results— Twelve Italian centers participated in the study. Patient data refer to bioprosthetic implantations performed from November 1988 to December 2009, which resulted in 6184 patients (mean age 71.3±5.4 years, 60.1% male) being enrolled. Of these patients, 1731 (27.9%) had type 2 DM. The propensity score–matching algorithm successfully matched 1113 patients with type 2 DM with the same number of no-DM patients. The postmatching standard differences were less than 0.1 for each of the covariates, and 64.2% of DM patients were matched. The early (30 days) mortality rate was 7.8% (n=87) versus 2.9% (n=33) in patients with or without type 2 DM ( P P Conclusions— Patients with type 2 DM undergoing bioprosthetic valve implantation are at high risk of early and long-term mortality, as well as of structural valve degeneration.

Details

ISSN :
15244539 and 00097322
Volume :
125
Issue :
4
Database :
OpenAIRE
Journal :
Circulation