Pulmonary Vein to Esophageal Fistula after Staged Hybrid Totally Thoracoscopic Surgical and Percutaneous Radiofrequency Catheter Ablation: A Case Report

Authors :
Dong Seop Jeong
Yong Soo Choi
Young Keun On
Byung-Jo Park
Yong Han Kim
Source :
The Korean Journal of Thoracic and Cardiovascular Surgery
Publication Year :
2014
Publisher :
The Korean Society for Thoracic and Cardiovascular Surgery, 2014.

Abstract

A case of a fistula running from the pulmonary vein to the esophagus after a staged hybrid procedure combining total thoracoscopic ablation and percutaneous radiofrequency catheter ablation has not been reported previously. We describe such a case in a 37-year-old man who was successfully treated by surgery.