Abstract
- Objective The Vascular Quality Initiative (VQI) is the largest registry of vascular surgical procedures and as such is capable of distinguishing small but important differences in outcomes. The goal of this study was to determine the outcomes of carotid endarterectomy (CEA) based on patch type, including bovine pericardium, autogenous vein, polytetrafluoroethylene (PTFE), and Dacron. Methods All primary CEAs performed with primary repair and patching (n = 70,987) within the VQI were retrospectively analyzed. Reoperative CEA and combined CEA and coronary artery bypass were excluded. Rates of any postoperative neurologic event, return to the operating room (bleeding, neurologic event, or wound complication), and restenosis (>50% and >80%) at 1-year follow-up were primary outcomes. Rates were compared by patch type using χ2 and Bonferroni analysis. Multivariate hierarchical logistic regression models were used to predict end points of postoperative neurologic event, return to the operating room, and 1-year restenosis. Results During the period of study, 2003 to 2017, there were 70,987 CEAs entered into the VQI registry. Bovine pericardium was the patch material with the highest frequency of use (n = 51,480), followed by Dacron (n = 12,356), vein (n = 1460), and PTFE (n = 1638). Bovine pericardium, vein, and Dacron had lower rates of postoperative neurologic events compared with PTFE or primary repair. Bovine pericardium had the lowest rate of restenosis at 1 year. By multivariate analysis, bovine pericardium (odds ratio [OR], 0.70; 95% confidence interval [CI], 0.56-0.89) and protamine use (OR, 0.74; 95% CI, 0.60-0.91) were associated with a lower incidence of return to the operating room. The use of Dacron, vein, and PTFE patches was not significantly different from the reference of primary closure. Multivariate analysis of postoperative neurologic events revealed that bovine pericardium (OR, 0.59; CI, 0.48-0.72) and Dacron (OR, 0.56; CI, 0.43-0.72) were associated with lower incidence of stroke or transient ischemic attack, whereas vein and PTFE were no different from primary closure. Bovine pericardium (OR, 0.57; CI, 0.44-0.75), Dacron (OR, 0.70; CI, 0.50-0.98), vein (OR, 0.72; CI, 0.53-0.98), and never smoking (OR, 0.87; CI, 0.78-0.96) were associated with a lower incidence of restenosis at 1 year by multivariate analysis. Conclusions Bovine pericardium has superior outcomes both postoperatively and at 1 year compared with other patch materials. The large volume of patient data contained in the VQI makes it possible to compare outcomes that have small but meaningful differences.
- Subjects :
- Male
Reoperation
medicine.medical_specialty
medicine.medical_treatment
Carotid endarterectomy
030204 cardiovascular system & hematology
Blood Vessel Prosthesis Implantation
03 medical and health sciences
0302 clinical medicine
Restenosis
Blood vessel prosthesis
medicine
Animals
Humans
Pericardium
Carotid Stenosis
Registries
030212 general & internal medicine
Vein
Polytetrafluoroethylene
Stroke
Aged
Retrospective Studies
Endarterectomy
Endarterectomy, Carotid
Polyethylene Terephthalates
business.industry
Odds ratio
medicine.disease
Blood Vessel Prosthesis
Surgery
medicine.anatomical_structure
cardiovascular system
Cattle
Female
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 07415214
- Volume :
- 71
- Database :
- OpenAIRE
- Journal :
- Journal of Vascular Surgery
- Accession number :
- edsair.doi.dedup.....01595742e4adef3017af34d6acb45bd8
- Full Text :
- https://doi.org/10.1016/j.jvs.2019.05.063