Back to Search
Start Over
Integrating quality assurance in autoimmunity: the changing face of the automated ANA IIF test
- Source :
- Clinical Chemistry and Laboratory Medicine (CCLM). 59:1247-1255
- Publication Year :
- 2021
- Publisher :
- Walter de Gruyter GmbH, 2021.
-
Abstract
- Objectives Currently available computer-aided diagnosis (CAD) systems for the detection of anti-nuclear antibodies (ANA) by indirect immunofluorescence (IIF) assay enable a standardized measurement of system-specific fluorescent intensity (FI) measures. We aimed to evaluate an internal quality control (iQC) program that controls the total ANA IIF process in routine practice. Methods In addition to the kit iQC materials, supplemental quality indicators were integrated in a total quality assurance (QA) program: patient-derived iQC’s samples (negative, 1/160 fine speckled and 1/160 homogeneous), median sample FI per run and percentage of ANA IIF positive samples per run. Analytical rejection criteria were based on the imprecision of the positivity index (PI) measure of the Zenit PRO system (Menarini). Clinical rejection criteria were based on changes in FI that correspond to a change in ANA IIF titer of ≥2. To evaluate the QA program, different artificial errors were introduced during the ANA IIF process. After every run, quality indicators were evaluated and compared to the pre-set target values. Results Rescanning the ANA IIF slides five times, using an old conjugate and a needle obstruction resulted in analytically and even clinically relevant errors in ANA IIF results. All errors were correctly detected by the different defined quality indicators. Traditional Westgard rules, including analytically (and clinically) defined rejection limits were useful in monitoring quality indicators. Conclusions The integration of a total process iQC program in CAD systems, based on the specific FI measurands and performance criteria of the system, adds value to QA.
- Subjects :
- Quality Control
0301 basic medicine
medicine.medical_specialty
Clinical Biochemistry
Autoimmunity
Routine practice
03 medical and health sciences
0302 clinical medicine
medicine
Humans
Medical physics
Fine speckled
Fluorescent Antibody Technique, Indirect
030203 arthritis & rheumatology
Indirect immunofluorescence
Diagnostic Tests, Routine
business.industry
Biochemistry (medical)
IIf
General Medicine
Cad system
Internal quality
030104 developmental biology
Homogeneous
Antibodies, Antinuclear
business
Quality assurance
Subjects
Details
- ISSN :
- 14374331 and 14346621
- Volume :
- 59
- Database :
- OpenAIRE
- Journal :
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Accession number :
- edsair.doi.dedup.....022b4875e362442acc78f445da1cd543