Back to Search
Start Over
Yield and Integrity of RNA from Brain Samples are Largely Unaffected by Pre-analytical Procedures
- Source :
- Neurochemical Research. 46:447-454
- Publication Year :
- 2020
- Publisher :
- Springer Science and Business Media LLC, 2020.
-
Abstract
- Gene expression studies are reported to be influenced by pre-analytical factors that can compromise RNA yield and integrity, which in turn may confound the experimental findings. Here we investigate the impact of four pre-analytical factors on brain-derived RNA: time-before-collection, tissue specimen size, tissue collection method, and RNA isolation method. We report no significant differences in RNA yield or integrity between 20 mg and 60 mg tissue samples collected in either liquid nitrogen or the RNAlater stabilizing solution. Isolation of RNA employing the TRIzol reagent resulted in a higher yield compared to isolation via the QIAcube kit while the latter resulted in RNA of slightly better integrity. Keeping brain tissue samples at room temperature for up to 160 min prior to collection and isolation of RNA resulted in no significant difference in yield or integrity. Our findings have significant practical and financial consequences for clinical genomic departments and other laboratory settings performing large-scale routine RNA expression analysis of brain samples.
- Subjects :
- 0301 basic medicine
RNA Stability
Time Factors
Brain tissue
Biochemistry
Specimen Handling
Mice
03 medical and health sciences
Cellular and Molecular Neuroscience
0302 clinical medicine
Gene expression
Animals
Tissue Collection
Chemistry
Temperature
Brain
RNA
General Medicine
030104 developmental biology
Trizol
Yield (chemistry)
RNA extraction
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 15736903 and 03643190
- Volume :
- 46
- Database :
- OpenAIRE
- Journal :
- Neurochemical Research
- Accession number :
- edsair.doi.dedup.....045e4b79dca43df817bb0e8935e32b74