Back to Search
Start Over
Rapid Detection of Ractopamine and Salbutamol in Swine Urine by Immunochromatography Based on Selenium Nanoparticles
- Source :
- International Journal of Nanomedicine
- Publication Year :
- 2020
-
Abstract
- Zhizeng Wang,1,* Qianqwen Zhou,1,* Yafei Guo,2,* Hangzhan Hu,1 Zhi Zheng,1 Shulian Li,1 Yaohui Wang,1 Yuanfang Ma1 1Joint National Laboratory for Antibody Drug Engineering, School of Basic Medical Sciences, Henan University, Kaifeng, 475004, People’s Republic of China; 2School of Laboratory, Sanquan college of Xinxiang Medical University, Xinxiang, Henan, 453003, People’s Republic of China*These authors contributed equally to this workCorrespondence: Yaohui Wang; Yuanfang MaJoint National Laboratory for Antibody Drug Engineering, School of Basic Medical Sciences, Henan University, Kaifeng, 475004, People’s Republic of ChinaTel +86 18237816739; +86 13803786139Email wangyaohui2001@sina.com; mayf@henu.edu.cnPurpose: The purpose of this study was to establish a lateral flow immunoassay using selenium nanoparticles (Se-NPs) as a probe to detect ractopamine (RAC) and salbutamol (SAL) in swine urine.Methods: SDS and PEG were used as templates to prepare Se-NPs; anti-RAC monoclonal antibodies or anti-SAL monoclonal antibodies were labelled with Se-NPs; and rapid detection kits were prepared. The sensitivity, specificity, and stability were measured, and actual samples were analysed.Results: The Se-NPs were spherical with a diameter of 40.63 ± 5.91 nm, and were conjugated successfully with an anti-RAC antibody to give a total diameter of 82.33 ± 17.91 nm. The detection limit of a RAC kit in swine urine was 1 ng/mL, and that of a SAL kit was 3 ng/mL. Both procedures could be completed within 5 minutes. No cross-reaction occurred with clenbuterol, bambuterol and phenylethanolamine A. Samples were tested consistently across different batches of kits for swine urine. The results of the kits were identical to those of actual clinical samples analysed by ELISA, and the coincidence rate was 100%.Conclusion: The assay kit does not require any special device for reading the results, and the readout is a simple colour change that can be evaluated with the naked eye. It is easy to operate, sensitive, specific, and stable This kit is suitable for the rapid and real-time detection of RAC and SAL residues in swine urine samples.Clinical Trial Registration: Swine urines samples were used under approval from the Experimental Animal Ethics committee of the Joint National Laboratory for Antibody Drug Engineering, Henan University.Keywords: ractopamine, salbutamol, lateral flow, selenium nanoparticles
- Subjects :
- medicine.drug_class
Swine
Biophysics
Pharmaceutical Science
chemistry.chemical_element
Metal Nanoparticles
Bioengineering
02 engineering and technology
010402 general chemistry
Monoclonal antibody
01 natural sciences
Antibodies
Chromatography, Affinity
Biomaterials
chemistry.chemical_compound
Selenium
International Journal of Nanomedicine
Drug Discovery
PEG ratio
Phenethylamines
selenium nanoparticles
medicine
Animals
Albuterol
Bambuterol
Original Research
Detection limit
Chromatography
Chemistry
Organic Chemistry
General Medicine
Hydrogen-Ion Concentration
021001 nanoscience & nanotechnology
0104 chemical sciences
Ractopamine
lateral flow
Clenbuterol
salbutamol
Salbutamol
ractopamine
0210 nano-technology
medicine.drug
Subjects
Details
- ISSN :
- 11782013
- Volume :
- 16
- Database :
- OpenAIRE
- Journal :
- International journal of nanomedicine
- Accession number :
- edsair.doi.dedup.....04d0772f42901cbbbfae5379e6996bcb