Back to Search Start Over

Characterization of collisionally pumped optical-field-ionization soft X-ray lasers

Authors :
Tomas Mocek
L. M. Upcraft
David Ros
Pierre Breger
I. Bettaibi
Philippe Balcou
Annie Klisnick
J.-F. Wyart
Antoine Carillon
Gerard Jamelot
Bedřich Rus
Stéphane Sebban
S. Le Pape
Philippe Zeitoun
Laboratoire d'optique appliquée (LOA)
École Nationale Supérieure de Techniques Avancées (ENSTA Paris)-École polytechnique (X)-Centre National de la Recherche Scientifique (CNRS)
Service des Photons, Atomes et Molécules (SPAM)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)
Laboratoire d'interaction du rayonnement X avec la matière (LIXAM)
Université Paris-Sud - Paris 11 (UP11)-Centre National de la Recherche Scientifique (CNRS)
Department of X Ray Lasers
institute of physics PALS center
Laboratoire Aimé Cotton (LAC)
Centre National de la Recherche Scientifique (CNRS)-Université Paris-Sud - Paris 11 (UP11)-École normale supérieure - Cachan (ENS Cachan)
École normale supérieure - Cachan (ENS Cachan)-Université Paris-Sud - Paris 11 (UP11)-Centre National de la Recherche Scientifique (CNRS)
Source :
Applied Physics B-Laser and Optics, Applied Physics B-Laser and Optics, Springer Verlag, 2004, 78 (7-8), pp.939-944. ⟨10.1007/s00340-004-1436-3⟩, Applied Physics B-Laser and Optics, 2004, 78 (7-8), pp.939-944. ⟨10.1007/s00340-004-1436-3⟩
Publication Year :
2004
Publisher :
HAL CCSD, 2004.

Abstract

We give an overview of recent experimental results on optical-field-ionization collisional soft X-ray lasers developed at LOA. By focusing a 30-fs, circularly polarized Ti-sapphire laser pulse at an intensity of up to 8×1017 Wcm-2 into a low-density gas cell containing Xe or Kr, we produced a few mm long plasma column for soft X-ray amplifier. Saturated amplification has been achieved on the 4d95d(1 S 0)–4d95p(1 P 1) transition at 41.8 nm in Xe8+, and on the 3d94d(1 S 0)–3d94p(1 P 1) transition in Kr8+ at 32.8 nm. Under optimum pumping conditions the Xe8+ laser provides about (5±2)×109 photons per pulse whilst the Kr8+ laser delivers up to (2.5±1)×109 photons per shot. The repetition rate of these soft X-ray lasers is 10 Hz. The beam wavefront of the Xe8+ laser has been measured by a Shack–Hartmann soft X-ray wavefront sensor, and the pulse duration by a cross-correlation technique.

Details

Language :
English
ISSN :
09462171
Database :
OpenAIRE
Journal :
Applied Physics B-Laser and Optics, Applied Physics B-Laser and Optics, Springer Verlag, 2004, 78 (7-8), pp.939-944. ⟨10.1007/s00340-004-1436-3⟩, Applied Physics B-Laser and Optics, 2004, 78 (7-8), pp.939-944. ⟨10.1007/s00340-004-1436-3⟩
Accession number :
edsair.doi.dedup.....051c2aff84437d1f48a8fc5ebf791b07
Full Text :
https://doi.org/10.1007/s00340-004-1436-3⟩