Back to Search Start Over

Aortic Curvature Instead of Angulation Allows Improved Estimation of the True Aorto-iliac Trajectory

Authors :
L. Kuster
Anco C. Vahl
D.A.F. van den Heuvel
Kenneth Ouriel
C.H. Slump
J.P.P.M. de Vries
Richte C.L. Schuurmann
Source :
European journal of vascular and endovascular surgery, 51(2), 216-224. W.B. Saunders Ltd
Publication Year :
2016
Publisher :
Elsevier BV, 2016.

Abstract

Objective: Supra- and infrarenal aortic neck angulation have been associated with complications after endovascular aortic aneurysm repair. However, a uniform angulation measurement method is lacking and the concept of angulation suggests a triangular oversimplification of the aortic anatomy. (Semi-)automated calculation of curvature along the center luminal line describes the actual trajectory of the aorta. This study proposes a methodology for calculating aortic (neck) curvature and suggests an additional method based on available tools in current workstations: curvature by digital calipers (CDC). Methods: Proprietary custom software was developed for automatic calculation of the severity and location of the largest supra- and infrarenal curvature over the center luminal line. Twenty-four patients with severe supra- or infrarenal angulations (≥45°) and 11 patients with small to moderate angulations (

Details

ISSN :
10785884
Volume :
51
Database :
OpenAIRE
Journal :
European Journal of Vascular and Endovascular Surgery
Accession number :
edsair.doi.dedup.....064131106beb3b50b3f482977cd4caba
Full Text :
https://doi.org/10.1016/j.ejvs.2015.09.008