Back to Search Start Over

A study on the thermal performance of exterior walls covered with a recently patented silica-aerogel-based insulating coating

Authors :
Etienne Wurtz
Pascal Henry Biwole
Mohamad Nasir Mohamad Ibrahim
Patrick Achard
Centre Procédés, Énergies Renouvelables, Systèmes Énergétiques (PERSEE)
Mines Paris - PSL (École nationale supérieure des mines de Paris)
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Centre National de la Recherche Scientifique (CNRS)
Laboratoire Jean Alexandre Dieudonné (LJAD)
Université Nice Sophia Antipolis (1965 - 2019) (UNS)
COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-Centre National de la Recherche Scientifique (CNRS)-Université Côte d'Azur (UCA)
Département des Technologies Solaires (DTS)
Laboratoire d'Innovation pour les Technologies des Energies Nouvelles et les nanomatériaux (LITEN)
Institut National de L'Energie Solaire (INES)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Savoie Mont Blanc (USMB [Université de Savoie] [Université de Chambéry])-Centre National de la Recherche Scientifique (CNRS)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Savoie Mont Blanc (USMB [Université de Savoie] [Université de Chambéry])-Centre National de la Recherche Scientifique (CNRS)-Institut National de L'Energie Solaire (INES)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Savoie Mont Blanc (USMB [Université de Savoie] [Université de Chambéry])-Centre National de la Recherche Scientifique (CNRS)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Savoie Mont Blanc (USMB [Université de Savoie] [Université de Chambéry])-Centre National de la Recherche Scientifique (CNRS)
MINES ParisTech - École nationale supérieure des mines de Paris
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)
Laboratoire Jean Alexandre Dieudonné (JAD)
Université Côte d'Azur (UCA)-Université Nice Sophia Antipolis (... - 2019) (UNS)
COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-COMUE Université Côte d'Azur (2015-2019) (COMUE UCA)-Centre National de la Recherche Scientifique (CNRS)
Source :
Building and Environment, Building and Environment, 2014, 81, pp.112-122. ⟨10.1016/j.buildenv.2014.06.017⟩, Building and Environment, Elsevier, 2014, 81, pp.112-122. ⟨10.1016/j.buildenv.2014.06.017⟩
Publication Year :
2014
Publisher :
Elsevier BV, 2014.

Abstract

International audience; This study aims at examining the energy behaviour of the buildings' multi-layer exterior wall structures. Most of the studies dealing with this issue have considered a continuous operation of the cooling/heating systems. Our objective here is to find the best wall structure and the number and position of insulation layers within exterior walls for continuous heating, intermittent heating, and no heating operation modes for some commonly used construction materials. Furthermore, among the different materials used, a recently patented insulating coating based on the (super)-insulating materials "Silica Aerogels" is being assessed. Results from a one-dimensional heat transfer numerical model in a multi-layer wall structure are compared to on-site measurements of an experimental set-up, having the new aerogel-based coating, under real weather conditions. The numerical model is then used to carry out all the simulations. Several assessment parameters are used: time lag, decrement factor, energy consumption, and thermal comfort index. Results show that for continuous and no heating cases, the best wall from maximum time lag and minimum decrement factor perspective is dividing the insulation layer into two and placing one at the middle of the wall and one at the exterior surface. For intermittently heated spaces, placing the insulation material as one layer at the interior wall surface is the most efficient from an energy consumption perspective. Also, when using the thermal comfort index for the no heating operation mode, the best performance is achieved when placing the insulation at the interior wall surface. For most of the cases studied, the aerogel-based insulating coating shows better performance than other insulating materials.

Details

ISSN :
03601323
Volume :
81
Database :
OpenAIRE
Journal :
Building and Environment
Accession number :
edsair.doi.dedup.....069ab532eb7e2eab9a96fe8dca6bef3b