Back to Search
Start Over
Black-Blood Multicontrast Imaging of Carotid Arteries with DANTE-prepared 2D and 3D MR Imaging
- Source :
- Radiology. 273:560-569
- Publication Year :
- 2014
- Publisher :
- Radiological Society of North America (RSNA), 2014.
-
Abstract
- PURPOSE: To prospectively compare the black-blood ( BB black blood ) imaging efficiency of a delay alternating with nutation for tailored excitation ( DANTE delay alternating with nutation for tailored excitation ) preparation module with conventional double inversion-recovery ( DIR double inversion recovery ) and motion-sensitive driven equilibrium ( MSDE motion-sensitive driven equilibrium ) preparation modules and to introduce a new three-dimensional ( 3D three-dimensional ) T1-weighted magnetic resonance (MR) imaging sequence. MATERIALS AND METHODS: Carotid artery wall imaging was performed in 10 healthy volunteers and 15 patients in accordance with an institutional review board-approved protocol. Two-dimensional ( 2D two-dimensional ) turbo spin-echo ( TSE turbo spin echo ) and 3D three-dimensional fast low-angle shot ( FLASH fast low-angle shot ) sequences served as readout modules. DANTE delay alternating with nutation for tailored excitation -prepared T1-, T2-, and proton density-weighted 2D two-dimensional TSE turbo spin echo images, as well as T1-weighted 3D three-dimensional DANTE delay alternating with nutation for tailored excitation -prepared FLASH fast low-angle shot (hereafter, 3D three-dimensional DASH DANTE-prepared FLASH ) images, were acquired in the region of the carotid artery bifurcation. For comparison, 2D two-dimensional DIR double inversion recovery -prepared, 2D two-dimensional MSDE motion-sensitive driven equilibrium -prepared multicontrast TSE turbo spin echo , and 3D three-dimensional MSDE motion-sensitive driven equilibrium -prepared FLASH fast low-angle shot (hereafter, 3D three-dimensional MERGE MSDE-prepared FLASH ) MR images were also acquired. The effective contrast-to-noise ratio ( CNReff effective contrast-to-noise ratio ) per unit time was calculated for all sequences. Paired t tests were performed to test within-group differences in vessel wall CNReff effective contrast-to-noise ratio . RESULTS: The CNReff effective contrast-to-noise ratio of DANTE delay alternating with nutation for tailored excitation -prepared T1-, T2-, and proton density-weighted sequences was 27.3, 14.7, and 25.7 mm(-1)min(-1/2), respectively; this represented an improvement of approximately 25%-100% (P < .05) when compared with the CNReff effective contrast-to-noise ratio attained with existing methods. The 3D three-dimensional DASH DANTE-prepared FLASH technique proved to be a fast (
- Subjects :
- Adult
Male
Adolescent
business.industry
Carotid arteries
Power deposition
Black blood
Middle Aged
Signal-To-Noise Ratio
Mr imaging
Time efficient
Imaging, Three-Dimensional
Imaging Tool
Nuclear magnetic resonance
Case-Control Studies
Image Interpretation, Computer-Assisted
Humans
Medicine
Image acquisition
Carotid Stenosis
Radiology, Nuclear Medicine and imaging
business
Magnetic Resonance Angiography
Aged
Biomedical engineering
Subjects
Details
- ISSN :
- 15271315 and 00338419
- Volume :
- 273
- Database :
- OpenAIRE
- Journal :
- Radiology
- Accession number :
- edsair.doi.dedup.....07ce25af9226362e75bd7fd389895e07
- Full Text :
- https://doi.org/10.1148/radiol.14131717