Back to Search Start Over

Safety of focused ultrasound neuromodulation in humans with temporal lobe epilepsy

Authors :
Alexander Bystritsky
Mark E. Schafer
Taylor Kuhn
Sheldon E. Jordan
John M. Stern
Itzhak Fried
Negar Khanlou
Inna Keselman
William H. Yong
Norman M. Spivak
Alexander S. Korb
Patricia D. Walshaw
David Kronemyer
Samuel D. Reyes
Mark S. Cohen
Martin M. Monti
Sergio Becerra
Jerome Engel
Caroline Schnakers
Source :
Brain Stimulation, Vol 14, Iss 4, Pp 1022-1031 (2021)
Publication Year :
2021

Abstract

Objective Transcranial Focused Ultrasound (tFUS) is a promising new potential neuromodulation tool. However, the safety of tFUS neuromodulation has not yet been assessed adequately. Patients with refractory temporal lobe epilepsy electing to undergo an anterior temporal lobe resection present a unique opportunity to evaluate the safety and efficacy of tFUS neuromodulation. Histological changes in tissue after tFUS can be examined after surgical resection, while further potential safety concerns can be assessed using neuropsychological testing. Methods Neuropsychological functions were assessed in eight patients before and after focused ultrasound sonication of the temporal lobe at intensities up to 5760 mW/cm2. Using the BrainSonix Pulsar 1002, tFUS was delivered under MR guidance, using the Siemens Magnetom 3T Prisma scanner. Neuropsychological changes were assessed using various batteries. Histological changes were assessed using hematoxylin and eosin staining, among others. Results With respect to safety, the histological analysis did not reveal any detectable damage to the tissue, except for one subject for whom the histology findings were inconclusive. In addition, neuropsychological testing did not show any statistically significant changes in any test, except for a slight decrease in performance on one of the tests after tFUS. Significance This study supports the hypothesis that low-intensity Transcranial Focused Ultrasound (tFUS) used for neuromodulation of brain circuits at intensities up to 5760 mW/cm2 may be safe for use in human research. However, due to methodological limitations in this study and inconclusive findings, more work is warranted to establish the safety. Future directions include greater number of sonications as well as longer exposure at higher intensity levels to further assess the safety of tFUS for modulation of neuronal circuits.

Details

ISSN :
18764754
Volume :
14
Issue :
4
Database :
OpenAIRE
Journal :
Brain stimulation
Accession number :
edsair.doi.dedup.....0853fa591058353e9634ef35f91d8f6d