Back to Search Start Over

Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention:The SORT OUT VII Trial

Authors :
Klara Berencsi
Hans-Henrik Tilsted
Morten Madsen
Anton Boel Villadsen
Lisette Okkels Jensen
Hans Erik Bøtker
Henrik Steen Hansen
Lars Romer Krusell
Evald Høj Christiansen
Anders Junker
Anne Kaltoft
Christian Juhl Terkelsen
Bent Raungaard
Per Thayssen
Svend Eggert Jensen
Michael Maeng
Jan Ravkilde
Jens Flensted Lassen
Steen Dalby Kristensen
Knud Nørregaard Hansen
Karsten Tange Veien
Jens Aarøe
Source :
Jensen, L O, Thayssen, P, Maeng, M, Ravkilde, J, Krusell, L R, Raungaard, B, Junker, A, Terkelsen, C J, Veien, K T, Villadsen, A B, Kaltoft, A, Tilsted, H-H, Hansen, K N, Aaroe, J, Kristensen, S D, Hansen, H S, Jensen, S E, Madsen, M, Bøtker, H E, Berencsi, K, Lassen, J F & Christiansen, E H 2016, ' Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention : The SORT OUT VII Trial ', Circulation: Cardiovascular Interventions, vol. 9, no. 7, e003610 . https://doi.org/10.1161/CIRCINTERVENTIONS.115.003610, Jensen, L O, Thayssen, P, Maeng, M, Ravkilde, J, Krusell, L R, Raungaard, B, Junker, A, Terkelsen, C J, Veien, K T, Villadsen, A B, Kaltoft, A, Tilsted, H-H, Hansen, K N, Aaroe, J, Dalby Kristensen, S, Hansen, H S, Jensen, S E, Madsen, M, Bøtker, H E, Berencsi, K, Lassen, J F & Christiansen, E H 2016, ' Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention : The SORT OUT VII Trial ', Circulation. Cardiovascular Interventions, vol. 9, no. 7, e003610 . https://doi.org/10.1161/circinterventions.115.003610, Jensen, L O, Thayssen, P, Maeng, M, Ravkilde, J, Krusell, L R, Raungaard, B, Junker, A, Terkelsen, C J, Veien, K T, Villadsen, A B, Kaltoft, A, Tilsted, H-H, Hansen, K N, Aaroe, J, Kristensen, S D, Hansen, H S, Jensen, S E, Madsen, M, Bøtker, H E, Berencsi, K, Lassen, J F & Christiansen, E H 2016, ' Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention : The SORT OUT VII Trial ', Circulation. Cardiovascular Interventions (Online), vol. 9, no. 7 . https://doi.org/10.1161/CIRCINTERVENTIONS.115.003610
Publication Year :
2016

Abstract

Background— Coronary drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy. Methods and Results— The Scandinavian Organization for Randomized Trials With Clinical Outcome (SORT OUT) VII trial—a large-scale registry-based randomized, multicenter, single-blind, 2-arm, noninferiority trial—compared 2 biodegradable polymer drug-eluting stents: the thin-strut cobalt–chromium sirolimus-eluting Orsiro stent and the stainless steel biolimus-eluting Nobori stent in an all-comer patient population. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 1 year, analyzed by intention to treat (noninferiority margin of 3.0%). Clinically driven event detection based on Danish registries was used. A total of 1261 patients were assigned to receive the sirolimus-eluting stent (1590 lesions) and 1264 patients to the biolimus-eluting stent (1588 lesions). At 1 year, the composite end point target lesion failure occurred in 48 patients (3.8%) in the sirolimus-eluting group and in 58 patients (4.6%) in the biolimus-eluting group (absolute risk difference, −0.78% [upper limit of 1-sided 95% confidence interval, 0.61%]; P P =0.034), which largely was attributable to a lower risk of subacute definite stent thrombosis: 0.1% versus 0.6% (rate ratio, 0.12; 95% confidence interval, 0.02–1.00; P =0.05). Conclusions— The thin-strut sirolimus-eluting Orsiro stent was noninferior to the biolimus-eluting Nobori stent in unselected patients for target lesion failure at 1 year. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT01879358.

Details

Language :
English
Database :
OpenAIRE
Journal :
Jensen, L O, Thayssen, P, Maeng, M, Ravkilde, J, Krusell, L R, Raungaard, B, Junker, A, Terkelsen, C J, Veien, K T, Villadsen, A B, Kaltoft, A, Tilsted, H-H, Hansen, K N, Aaroe, J, Kristensen, S D, Hansen, H S, Jensen, S E, Madsen, M, Bøtker, H E, Berencsi, K, Lassen, J F & Christiansen, E H 2016, ' Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention : The SORT OUT VII Trial ', Circulation: Cardiovascular Interventions, vol. 9, no. 7, e003610 . https://doi.org/10.1161/CIRCINTERVENTIONS.115.003610, Jensen, L O, Thayssen, P, Maeng, M, Ravkilde, J, Krusell, L R, Raungaard, B, Junker, A, Terkelsen, C J, Veien, K T, Villadsen, A B, Kaltoft, A, Tilsted, H-H, Hansen, K N, Aaroe, J, Dalby Kristensen, S, Hansen, H S, Jensen, S E, Madsen, M, Bøtker, H E, Berencsi, K, Lassen, J F & Christiansen, E H 2016, ' Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention : The SORT OUT VII Trial ', Circulation. Cardiovascular Interventions, vol. 9, no. 7, e003610 . https://doi.org/10.1161/circinterventions.115.003610, Jensen, L O, Thayssen, P, Maeng, M, Ravkilde, J, Krusell, L R, Raungaard, B, Junker, A, Terkelsen, C J, Veien, K T, Villadsen, A B, Kaltoft, A, Tilsted, H-H, Hansen, K N, Aaroe, J, Kristensen, S D, Hansen, H S, Jensen, S E, Madsen, M, Bøtker, H E, Berencsi, K, Lassen, J F & Christiansen, E H 2016, ' Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention : The SORT OUT VII Trial ', Circulation. Cardiovascular Interventions (Online), vol. 9, no. 7 . https://doi.org/10.1161/CIRCINTERVENTIONS.115.003610
Accession number :
edsair.doi.dedup.....0862408bc41a5059b9aff99be572bc52
Full Text :
https://doi.org/10.1161/CIRCINTERVENTIONS.115.003610