Back to Search Start Over

Aortic compliance in human hypertension

Authors :
Frank C.P. Yin
S X Zhu
Chih Tai Ting
Z R Liu
Source :
Hypertension (Dallas, Tex. : 1979). 14(2)
Publication Year :
1989

Abstract

Aortic compliance in normotensive and hypertensive Chinese subjects undergoing diagnostic cardiac catheterization was compared by using a newly described method that allows for determination of the pressure dependence of compliance if one assumes a value for the exponential coefficient of the pressure-volume relation of the large arteries. Under baseline conditions in the normotensive and hypertensive groups at mean aortic pressures of 96.3 and 128.6 mm Hg, aortic compliance averaged 1.47 and 0.80 ml/mm Hg, respectively. Compliance in the hypertensive group at a diastolic pressure of 99.4 mm Hg (which was nearly equal to the mean normotensive pressure) was 1.072 ml/mm Hg--still significantly lower than in the normotensive group. During nitroprusside infusion, however, the compliances in the hypertensive group increased to levels equal to or greater those in the normotensive group. Thus, these data confirm that aortic compliance is lower in hypertensive than in normotensive humans. They further demonstrate that the lower compliance cannot be attributed entirely to the elevated blood pressure, suggesting that excess smooth muscle tone may be partly responsible.

Details

ISSN :
0194911X
Volume :
14
Issue :
2
Database :
OpenAIRE
Journal :
Hypertension (Dallas, Tex. : 1979)
Accession number :
edsair.doi.dedup.....0b37913cf91f719adfed18b407a9638a