Back to Search
Start Over
Radiation exposure during direct versus indirect image acquisition during fluoroscopy-controlled internal fixation of a hip fracture: Results of a randomized controlled trial
- Source :
- Injury, 50(12), 2263-2267. Elsevier Ltd.
- Publication Year :
- 2019
-
Abstract
- Background : Intra-operative image acquisition can be obtained indirectly (via verbal request to a technician) or directly (executed at the tableside, by a surgeon stepping on a foot pedal). Direct image acquisition could reduce the exposure time and thus the risk of radiation damage. The aim of this randomized controlled trial was to compare direct surgeon-controlled fluoroscopy with indirect technician-operated fluoroscopy during internal fixation of a hip fracture. Methods : From March 5, 2014 to August 19, 2015, 100 patients who had sustained a hip fracture that required internal fixation were enrolled. Patients were randomized between direct surgeon-controlled image acquisition using a foot pedal (n=52) and indirect image acquisition by a radiology technician (n=48). The primary outcome measure was the radiation exposure time; secondary outcome measures were the associated effective radiation dose and the dose area product. (DAP) Results : A total of 96 patients (with a median age of 84 years) were enrolled in this study. Eighty-nine (93%) patients had a pertrochanteric fracture. No statistically significant differences between direct image acquisition and indirect image acquisition were found for overall radiation time, total radiation dose or DAP for the total population. When adjusted for potential confounders, a difference in overall radiation time of 18.50 seconds (95% CI 2.19; 34.81, p=0.027) was found in favour of indirect image acquisition. Conclusion : This study showed statistically significantly lower radiation duration using indirect fluoroscopy for the total population and the pertrochanteric fracture subgroup when adjusted for several confounders. No significant effect on radiation dose and DAP was found.
- Subjects :
- Male
medicine.medical_treatment
Radiation Dosage
law.invention
03 medical and health sciences
Fracture Fixation, Internal
0302 clinical medicine
Randomized controlled trial
law
medicine
Internal fixation
Fluoroscopy
Image acquisition
Humans
General Environmental Science
Aged, 80 and over
030222 orthopedics
Hip fracture
medicine.diagnostic_test
business.industry
Hip Fractures
Confounding
030208 emergency & critical care medicine
Radiation Exposure
medicine.disease
Outcome and Process Assessment, Health Care
Surgery, Computer-Assisted
Dose area product
General Earth and Planetary Sciences
Female
Radiation protection
Nuclear medicine
business
Femoral Fractures
Subjects
Details
- ISSN :
- 00201383
- Volume :
- 50
- Issue :
- 12
- Database :
- OpenAIRE
- Journal :
- Injury
- Accession number :
- edsair.doi.dedup.....0b885de1ece630e6e7f1051ff5f1b142