Back to Search
Start Over
Quantifying the performance of two different types of commercial software programs for 3D patient dose reconstruction for prostate cancer patients: Machine log files vs. machine log files with EPID images
- Source :
- Physica Medica. 45:170-176
- Publication Year :
- 2018
- Publisher :
- Elsevier BV, 2018.
-
Abstract
- We clarified the reconstructed 3D dose difference between two different commercial software programs (Mobius3D v2.0 and PerFRACTION v1.6.4). Five prostate cancer patients treated with IMRT (74 Gy/37 Fr) were studied. Log files and cine EPID images were acquired for each fraction. 3D patient dose was reconstructed using log files (Mobius3D) or log files with EPID imaging (PerFRACTION). The treatment planning dose was re-calculated on homogeneous and heterogeneous phantoms, and log files and cine EPID images were acquired. Measured doses were compared with the reconstructed point doses in the phantom. Next, we compared dosimetric metrics (mean dose for PTV, rectum, and bladder) calculated by Mobius3D and PerFRACTION for all fractions from five patients. Dose difference at isocenter between measurement and reconstructed dose for two software programs was within 3.0% in both homogeneous and heterogeneous phantoms. Moreover, the dose difference was larger using skip arc plan than that using full arc plan, especially for PerFRACTION (e.g., dose difference at isocenter for PerFRACTION: 0.34% for full arc plan vs. -4.50% for skip arc plan in patient 1). For patients, differences in dosimetric parameters were within 1% for almost all fractions. PerFRACTION had wider range of dose difference between first fraction and the other fractions than Mobius3D (e.g., maximum difference: 0.50% for Mobius3D vs. 1.85% for PerFRACTION), possibly because EPID may detect some types of MLC positioning errors such as miscalibration errors or mechanical backlash which cannot be detected by log files, or that EPID data might include image acquisition failure and image noise.
- Subjects :
- Male
Models, Anatomic
Biophysics
General Physics and Astronomy
Imaging phantom
030218 nuclear medicine & medical imaging
03 medical and health sciences
Imaging, Three-Dimensional
0302 clinical medicine
Image noise
Humans
Radiology, Nuclear Medicine and imaging
Fraction (mathematics)
In patient
Radiation treatment planning
Mathematics
Commercial software
Phantoms, Imaging
business.industry
Radiotherapy Planning, Computer-Assisted
Prostatic Neoplasms
Water
Isocenter
Femur Head
Radiotherapy Dosage
General Medicine
030220 oncology & carcinogenesis
Patient dose
Radiotherapy, Intensity-Modulated
Nuclear medicine
business
Software
Subjects
Details
- ISSN :
- 11201797
- Volume :
- 45
- Database :
- OpenAIRE
- Journal :
- Physica Medica
- Accession number :
- edsair.doi.dedup.....0c2cc40504deeef27672a02ca9f54eb4
- Full Text :
- https://doi.org/10.1016/j.ejmp.2017.12.018