Detection and plasma pharmacokinetics of an anti-vascular endothelial growth factor oligonucleotide-aptamer (NX1838) in rhesus monkeys

Authors :
Mark B. Judkins
Stanley C. Gill
Long-Shiuh Chen
Chris Tucker
Daniel W. Drolet
James A. Farmer
Source :
Journal of Chromatography B: Biomedical Sciences and Applications. 732:203-212
Publication Year :
1999
Publisher :
Elsevier BV, 1999.

Abstract

Aptamers are oligonucleotide ligands selected, in vitro, to bind a specified target protein. The first aptamer to reach human clinical testing is NX1838, a polyethylene glycol conjugated aptamer that inhibits vascular endothelial growth factor. This paper describes the validation of a high-performance liquid chromatographic anion-exchange method for the determination of NX1838 in plasma. Measurements of intact NX1838 had a coefficient of variation of less than 8% and an accuracy between 107% and 115%. The assay was utilized to determine NX1838 plasma pharmacokinetics in rhesus monkeys following a single 1 mg/kg intravenous or subcutaneous dose. Following intravenous administration, the maximum achieved plasma concentration was 25.5 μg/ml with a terminal half-life of 9.3 h and clearance rate of 6.2 ml/h. After subcutaneous administration, the fraction of the dose absorbed into the plasma compartment was 0.78 with a time to peak concentration (4.9 μg/ml) of 8 to 12 h.