Back to Search
Start Over
Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study
- Source :
- European Radiology, European Radiology, Springer Verlag, 2020, 30 (7), pp.3951-3959. ⟨10.1007/s00330-020-06724-w⟩
- Publication Year :
- 2020
- Publisher :
- HAL CCSD, 2020.
-
Abstract
- To assess the impact on image quality and dose reduction of a new deep learning image reconstruction (DLIR) algorithm compared with a hybrid iterative reconstruction (IR) algorithm. Data acquisitions were performed at seven dose levels (CTDIvol : 15/10/7.5/5/2.5/1/0.5 mGy) using a standard phantom designed for image quality assessment. Raw data were reconstructed using the filtered back projection (FBP), two levels of IR (ASiR-V50% (AV50); ASiR-V100% (AV100)), and three levels of DLIR (TrueFidelity™ low, medium, high). Noise power spectrum (NPS) and task-based transfer function (TTF) were computed. Detectability index (d′) was computed to model a large mass in the liver, a small calcification, and a small subtle lesion with low contrast. NPS peaks were higher with AV50 than with all DLIR levels and only higher with DLIR-H than with AV100. The average NPS spatial frequencies were higher with DLIR than with IR. For all DLIR levels, TTF50% obtained with DLIR was higher than that with IR. d′ was higher with DLIR than with AV50 but lower with DLIR-L and DLIR-M than with AV100. d′ values were higher with DLIR-H than with AV100 for the small low-contrast lesion (10 ± 4%) and in the same range for the other simulated lesions. New DLIR algorithm reduced noise and improved spatial resolution and detectability without changing the noise texture. Images obtained with DLIR seem to indicate a greater potential for dose optimization than those with hybrid IR. • This study assessed the impact on image quality and radiation dose of a new deep learning image reconstruction (DLIR) algorithm as compared with hybrid iterative reconstruction (IR) algorithm. • The new DLIR algorithm reduced noise and improved spatial resolution and detectability without perceived alteration of the texture, commonly reported with IR. • As compared with IR, DLIR seems to open further possibility of dose optimization.
- Subjects :
- medicine.medical_specialty
Image quality
MESH: Radiographic Image Interpretation, Computer-Assisted / methods
Tomography, X-Ray Computed / methods
Iterative reconstruction
Radiation Dosage
Imaging phantom
030218 nuclear medicine & medical imaging
Multidetector computed tomography
03 medical and health sciences
0302 clinical medicine
[INFO.INFO-IM]Computer Science [cs]/Medical Imaging
Medicine
Humans
Radiology, Nuclear Medicine and imaging
Image resolution
Radon transform
business.industry
Phantoms, Imaging
MESH: Algorithms
Deep Learning
Ultrasound
Deep learning
General Medicine
Noise
030220 oncology & carcinogenesis
Image enhancement
Image reconstruction
Radiographic Image Interpretation, Computer-Assisted
Spatial frequency
Radiology
business
Tomography, X-Ray Computed
Algorithms
Biomedical engineering
Subjects
Details
- Language :
- English
- ISSN :
- 09387994 and 14321084
- Database :
- OpenAIRE
- Journal :
- European Radiology, European Radiology, Springer Verlag, 2020, 30 (7), pp.3951-3959. ⟨10.1007/s00330-020-06724-w⟩
- Accession number :
- edsair.doi.dedup.....0eee146d4f566aa27737e0e9332bac90
- Full Text :
- https://doi.org/10.1007/s00330-020-06724-w⟩