Back to Search
Start Over
Effect of decreasing column inner diameter and use of off-line two-dimensional chromatography on metabolite detection in complex mixtures
- Source :
- Journal of Chromatography A. 1172:127-134
- Publication Year :
- 2007
- Publisher :
- Elsevier BV, 2007.
-
Abstract
- Capillary liquid chromatography coupled with electrospray ionization to a quadropole ion trap mass spectrometer was explored as a method for the analysis of polar anionic compounds in complex metabolome mixtures. A ternary mobile phase gradient, consisting of aqueous acidic, aqueous neutral and organic phases in combination with an aqueous compatible reversed-phase stationary phase allowed metabolites with a wide range of polarities to be resolved and detected. Detection limits in the full scan mode for glycolysis and tricarboxylic acid cycle intermediates were from 0.9 to 36 fmol. Using this system, 111 ± 9 (n = 3) metabolites were detected in Escherichia coli lysate samples. Reducing column I.D. from 50 μm to 25μm increased the number of metabolites detected to 156 ± 17 (n = 3). The improvement in number of metabolites detected was attributed to an increase in separation efficiency, an increase in sensitivity, and a decrease in adduct formation. Implementation of a second separation mode, strong anion exchange, to fractionate the sample prior to capillary RPLC increased the number of metabolites detected to 244 ± 21 (n = 3). This improvement was attributed to the increased peak capacity which decreased co-elution of molecules enabling more sensitive detection by mass spectrometry. This system was also applied to islets of Langerhans where more significant improvements in metabolite detection were observed. In islets, 391 ± 33 small molecules were detected using the two-dimensional separation. The results demonstrate that column miniaturization and use of two-dimensional separations can yield a significant improvement in the coverage of the metabolome.
- Subjects :
- Spectrometry, Mass, Electrospray Ionization
Electrospray
Metabolite
Electrospray ionization
Analytical chemistry
Complex Mixtures
Mass spectrometry
Sensitivity and Specificity
Biochemistry
High-performance liquid chromatography
Article
Analytical Chemistry
Islets of Langerhans
Mice
chemistry.chemical_compound
Capillary Electrochromatography
Escherichia coli
Metabolome
Animals
Chromatography, High Pressure Liquid
Miniaturization
Chromatography
Organic Chemistry
Reproducibility of Results
General Medicine
Reversed-phase chromatography
Chromatography, Ion Exchange
Metabolism
chemistry
Two-dimensional chromatography
Hydrophobic and Hydrophilic Interactions
Subjects
Details
- ISSN :
- 00219673
- Volume :
- 1172
- Database :
- OpenAIRE
- Journal :
- Journal of Chromatography A
- Accession number :
- edsair.doi.dedup.....12011998422b68855cd14fcad0bcd3b2
- Full Text :
- https://doi.org/10.1016/j.chroma.2007.09.075