Back to Search
Start Over
Macro-reentrant atrial tachycardia after tricuspid or mitral valve surgery: is there difference in electrophysiological characteristics and effectiveness of catheter ablation?
- Source :
- BMC Cardiovascular Disorders, Vol 21, Iss 1, Pp 1-9 (2021), BMC Cardiovascular Disorders
- Publication Year :
- 2021
- Publisher :
- BMC, 2021.
-
Abstract
- Background Macro-reentrant atrial tachycardias (MATs) are a common complication after cardiac valve surgery. The MAT types and the effectiveness of MAT ablation might differ after different valve surgery. Data comparing the electrophysiological characteristics and the ablation results of MAT post-tricuspid or mitral valve surgery are limited. Methods Forty-eight patients (29 males, age 56.1 ± 13.3 years) with MAT after valve surgery were assigned to tricuspid valve (TV) group (n = 18) and mitral valve (MV) group (n = 30). MATs were mapped and ablated guided by a three-dimensional navigation system. The one-year clinical effectiveness was compared in two groups. Results Nineteen MATs were documented in TV group, including 16 cavo-tricuspid isthmus (CTI)-dependent AFL and 3 other MATs at right atrial (RA) free wall, RA septum and left atrial (LA) roof. Thirty-nine MATs were identified in MV group, including15 CTI-dependent AFL, 8 RA free wall scar-related, 2 RA septum scar-related, 8 peri-mitral flutter, 3 LA roof-dependent, 2 LA anterior scar-related, and 1 right pulmonary vein-related MAT. Compared with TV group, MV group had significantly lower prevalence of CTI-dependent AFL (38.5% vs. 84.2%), higher prevalence of left atrial MAT (35.9 vs.5.3%) and higher proportion of patients with left atrial MAT (40 vs. 5.6%), P = 0.02, 0.01 and 0.01, respectively. The acute success rate of MAT ablation (100 vs. 93.3%) and the one-year freedom from atrial tachy-arrhythmias (72.2 vs. 76.5%) was comparable in TV and MV group. No predictor for recurrence was identified. Conclusion Although the types of MATs differed significantly in patients with prior TV or MV surgery, the acute and mid-term effectiveness of MAT ablation was comparable in two groups. Trial registration: This study was registered as a part of EARLY-MYO-AF clinical trial at the website ClinicalTrials. gov (NCT04512222).
- Subjects :
- Male
medicine.medical_specialty
medicine.medical_treatment
Mitral valve surgery
Catheter ablation
Atrial flutter
Diagnosis, Differential
Electrocardiography
Tricuspid valve surgery
Postoperative Complications
Internal medicine
Mitral valve
Tachycardia
medicine
Humans
Diseases of the circulatory (Cardiovascular) system
Heart Atria
Atrial tachycardia
Angiology
Retrospective Studies
Tricuspid valve
business.industry
Research
Macro-reentrant atrial tachycardia
Middle Aged
medicine.disease
Ablation
Cardiac surgery
medicine.anatomical_structure
RC666-701
Cardiology
cardiovascular system
Mitral Valve
Female
Tricuspid Valve
medicine.symptom
Cardiology and Cardiovascular Medicine
business
Electrophysiologic Techniques, Cardiac
Subjects
Details
- Language :
- English
- ISSN :
- 14712261
- Volume :
- 21
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- BMC Cardiovascular Disorders
- Accession number :
- edsair.doi.dedup.....1324f3babd5ce67560c67de420f063c4