Back to Search
Start Over
Rapid measurement of fibrinogen concentration in whole blood using a steel ball coagulometer
- Source :
- The Journal of Trauma and Acute Care Surgery
- Publication Year :
- 2015
- Publisher :
- Ovid Technologies (Wolters Kluwer Health), 2015.
-
Abstract
- Supplemental digital content is available in the text.<br />BACKGROUND Fibrinogen plays a key role in hemostasis and is the first coagulation factor to reach critical levels in bleeding patients. Current European guidelines on the management of traumatic or perioperative bleeding recommend fibrinogen supplementation at specific threshold levels. Whole blood viscoelastic tests provide fast evaluation of fibrin deficits. Fast measurement of plasma fibrinogen concentration is not yet available. We investigated a method to rapidly determine whole blood fibrinogen concentration using standard Clauss assays and a steel ball coagulometer and provide an estimate of the “plasma-equivalent” fibrinogen concentration within minutes by adjustment of the measured whole blood fibrinogen concentration with a quickly measureable hemoglobin-derived hematocrit. METHODS The feasibility of this approach was tested with a Clauss assay using multiple porcine fresh blood samples obtained during in vivo bleeding, hemodilution, and after treatment with hemostatic therapy. Two different Clauss assays were then tested using multiple human volunteers’ blood samples diluted in vitro and supplemented with fibrinogen concentrate. Comparative measurements with fibrin-based thromboelastometry tests were performed. RESULTS Regression and Bland-Altman analyses of derived “plasma-equivalent” fibrinogen and measured plasma fibrinogen concentration was excellent in porcine and human blood samples, especially in the ranges relevant to traumatic or perioperative bleeding. CONCLUSION Fast whole blood fibrinogen measurements could be considered as an alternative to plasma fibrinogen measurement for acute bleeding management in trauma and perioperative care settings. Further studies are needed to prove this concept and determine the turnaround times for its clinical application in emergency departments and operating theaters.
- Subjects :
- medicine.medical_specialty
Swine
Hematocrit
Critical Care and Intensive Care Medicine
Fibrinogen
Fibrin
Internal medicine
medicine
Animals
Humans
Whole blood
Hemodilution
Hemostasis
medicine.diagnostic_test
biology
business.industry
clinical laboratory techniques
pigs
Original Articles
Hematology
Steel ball
Healthy Volunteers
Thrombelastography
Surgery
Coagulation
Steel
ComputingMethodologies_DOCUMENTANDTEXTPROCESSING
Cardiology
biology.protein
Feasibility Studies
business
Blood coagulation tests
medicine.drug
Subjects
Details
- ISSN :
- 21630755
- Volume :
- 78
- Database :
- OpenAIRE
- Journal :
- Journal of Trauma and Acute Care Surgery
- Accession number :
- edsair.doi.dedup.....134e100606638656b7a8c9264a0cd626
- Full Text :
- https://doi.org/10.1097/ta.0000000000000546