Back to Search
Start Over
A quality optimization approach to image Achilles tendon microstructure by phase-contrast enhanced synchrotron micro-tomography
- Source :
- Scientific Reports, Vol 11, Iss 1, Pp 1-14 (2021), Scientific Reports
- Publication Year :
- 2021
- Publisher :
- Nature Portfolio, 2021.
-
Abstract
- Achilles tendons are mechanosensitive, and their complex hierarchical structure is in part the result of the mechanical stimulation conveyed by the muscles. To fully understand how their microstructure responds to mechanical loading a non-invasive approach for 3D high resolution imaging suitable for soft tissue is required. Here we propose a protocol that can capture the complex 3D organization of the Achilles tendon microstructure, using phase-contrast enhanced synchrotron micro-tomography (SR-PhC-mu CT). We investigate the effects that sample preparation and imaging conditions have on the resulting image quality, by considering four types of sample preparations and two imaging setups (sub-micrometric and micrometric final pixel sizes). The image quality is assessed using four quantitative parameters. The results show that for studying tendon collagen fibers, conventional invasive sample preparations such as fixation and embedding are not necessary or advantageous. Instead, fresh frozen samples result in high-quality images that capture the complex 3D organization of tendon fibers in conditions as close as possible to natural. The comprehensive nature of this innovative study by SR-PhC-mu CT breaks ground for future studies of soft complex biological tissue in 3D with high resolution in close to natural conditions, which could be further used for in situ characterization of how soft tissue responds to mechanical stimuli on a microscopic level. Funding Agencies|Knut and Alice Wallenberg KAW FoundationKnut & Alice Wallenberg Foundation [2017.0221]; Carl Trygger Foundation [18:166]; European Unions Horizon 2020 research and innovation program under the Marie Skodowska-Curie Grant [701647]
- Subjects :
- Materials science
Image quality
Science
Achilles Tendon
Article
law.invention
Rats, Sprague-Dawley
Tendons
03 medical and health sciences
0302 clinical medicine
Imaging, Three-Dimensional
law
medicine
Animals
Microscopy, Phase-Contrast
030304 developmental biology
0303 health sciences
Achilles tendon
Multidisciplinary
Pixel
Medicinsk bildbehandling
Soft tissue
Reproducibility of Results
X-Ray Microtomography
Microstructure
Synchrotron
Tendon
Characterization (materials science)
Biomedical Enhancement
Medical Image Processing
medicine.anatomical_structure
Medicine
Female
X-ray tomography
030217 neurology & neurosurgery
Synchrotrons
Biomedical engineering
Subjects
Details
- Language :
- English
- ISSN :
- 20452322
- Volume :
- 11
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- Scientific Reports
- Accession number :
- edsair.doi.dedup.....15d4fb62661192fecf6814659b0d9f00