Influence of aneurysmal aortic root geometry on mechanical stress to the aortic valve leaflet

Authors :
Joseph Sanchez
Koji Takeda
Isaac Y. Wu
Paul Kurlansky
Yanling Zhao
Scott DeRoo
Koichi Akiyama
Hiroo Takayama
Giovanni Ferrari
Atsushi Kainuma
Keiichi Itatani
Melana Yuzefpolskaya
Paolo C. Colombo
Hideyuki Hayashi
Source :
European heart journal. Cardiovascular Imaging. 22(9)
Publication Year :
2020

Abstract

Aims While mechanical stress caused by blood flow, e.g. wall shear stress (WSS), and related parameters, e.g. oscillatory shear index (OSI), are increasingly being recognized as key moderators of various cardiovascular diseases, studies on valves have been limited because of a lack of appropriate imaging modalities. We investigated the influence of aortic root geometry on WSS and OSI on the aortic valve (AV) leaflet. Methods and results We applied our novel approach of intraoperative epi-aortic echocardiogram to measure the haemodynamic parameters of WSS and OSI on the AV leaflet. Thirty-six patients were included, which included those who underwent valve-sparing aortic root replacement (VSARR) with no significant aortic regurgitation (n = 17) and coronary artery bypass graft (CABG) with normal AV (n = 19). At baseline, those who underwent VSARR had a higher systolic WSS (0.52 ± 0.12 vs. 0.32 ± 0.08 Pa, respectively, P < 0.001) and a higher OSI (0.37 ± 0.06 vs. 0.29 ± 0.04, respectively, P < 0.001) on the aortic side of the AV leaflet than those who underwent CABG. Multivariate regression analysis revealed that the size of the sinus of Valsalva had a significant association with WSS and OSI. Following VSARR, WSS and OSI values decreased significantly compared with the baseline values (WSS: 0.29 ± 0.12 Pa, P < 0.001; OSI: 0.26 ± 0.09, P < 0.001), and became comparable to the values in those who underwent CABG (WSS, P = 0.42; OSI, P = 0.15). Conclusions Mechanical stress on the AV gets altered in correlation with the size of the aortic root. An aneurysmal aortic root may expose the leaflet to abnormal fluid dynamics. The VSARR procedure appeared to reduce these abnormalities.

Details

ISSN :
20472412
Volume :
22
Issue :
9
Database :
OpenAIRE
Journal :
European heart journal. Cardiovascular Imaging
Accession number :
edsair.doi.dedup.....1809f915bcf5bafa046a25ca4a8bd4b1