Back to Search Start Over

Reduced myelin in patients with isolated hippocampal sclerosis as assessed by SyMRI

Authors :
Burcak Bilginer
Kader Karli Oguz
Figen Soylemezoglu
Serap Saygi
Gökçen Çoban
Irsel Tezer
Jale Karakaya
Safak Parlak
Ekim Gumeler
Source :
Neuroradiology
Publication Year :
2021
Publisher :
Springer Science and Business Media LLC, 2021.

Abstract

Purpose Synthetic MRI (SyMRI) enables to quantify brain tissue and morphometry. We aimed to investigate the WM and myelin alterations in patients with unilateral hippocampal sclerosis (HS) with SyMRI. Methods Adult patients with isolated unilateral HS and age-matched control subjects (CSs) were included in this study. The SyMRI sequence QRAPMASTER in the coronal plane perpendicular to the hippocampi was obtained from the whole brain. Automatic segmentation of the whole brain was processed by SyMRI Diagnostic software (Version 11.2). Two neuroradiologists also performed quantitative analyses independently from symmetrical 14 ROIs placed in temporal and extratemporal WM, hippocampi, and amygdalae in both hemispheres. Results Sixteen patients (F/M = 6/10, mean age = 32.5 ± 11.3 years; right/left HS: 8/8) and 10 CSs (F/M = 5/5, mean age = 30.7 ± 7 years) were included. Left HS patients had significantly lower myelin and WM volumes than CSs (p

Details

ISSN :
14321920 and 00283940
Volume :
64
Database :
OpenAIRE
Journal :
Neuroradiology
Accession number :
edsair.doi.dedup.....185af4dbaf8bd7b047ba30d3882fbdcc
Full Text :
https://doi.org/10.1007/s00234-021-02824-6