Back to Search Start Over

The Usefulness of Biosynthetic Vascular Graft Omniflow II and Autologous Veins for the Treatment of Massive Infection of Dacron Vascular Graft with Enterococcus faecalis HLAR

Authors :
Robert Bajno
Piotr Ciostek
Witold Woźniak
Michał P. Świder
Source :
Polish Journal of Microbiology, Vol 65, Iss 4 (2016)
Publication Year :
2016
Publisher :
Polish Society of Microbiologists, 2016.

Abstract

Infections of vascular grafts are the most severe complications in vascular surgery. We present the case of a 73-year-old male with infection of a dacron prosthesis with a strain of Enterococcus faecalis. The patient was treated with replacement of a full prosthesis with a combined graft constructed from Biosynthetic Vascular graft Omniflow and autologous veins. This graft is recommended for implantation in patients with a higher risk of infection. Our case is one of the first reported usage of this kind of graft in the aortic region and in a 2 years observation period no recurrence of infection was observed.

Details

ISSN :
25444646
Volume :
65
Database :
OpenAIRE
Journal :
Polish Journal of Microbiology
Accession number :
edsair.doi.dedup.....18693416e67be7858d6ee10d10ad8bd7
Full Text :
https://doi.org/10.5604/17331331.1227674