No effect of femoral canal jet-lavage on the stability of cementless stems in primary hip arthroplasty: a randomised RSA study with 6 years follow-up
- Source :
- Hip international : the journal of clinical and experimental research on hip pathology and therapy. 30(4)
- Publication Year :
- 2019
-
Abstract
- Introduction: In contrast to cemented hip prostheses, the effect of washing the bone bed with jet-lavage prior to insertion of cementless stem components in primary hip arthroplasty (THA) is unclear. Jet-lavage potentially decreases the risk of fat embolisation during rasping and stem insertion and might help in avoiding bacterial contamination. An earlier animal study has shown less debris and better-organised trabecular structure of new bone when jet-lavage was used. We hypothesised that the primary stability of cementless femoral stems implanted after jet-lavage of the femoral canal prior to stem insertion would improve with earlier stabilisation, as measured with Radiostereometry (RSA), compared with insertion without prior jet-lavage. Methods: 40 patients with primary osteoarthritis operated on with a cementless titanium grit blasted stem are included in the study. The patients were randomised to either jet-lavage or control without any lavage of the femoral canal prior to insertion of the prosthesis. The stem migration pattern was measured with RSA at 0, 3, 12, 24 and 72 months. Results: At 6 years, 19 patients remained for analysis in the jet-lavage and 18 in the control group. We found no difference in extent or pattern of migration as measured with RSA. Both groups seemed to have stabilised within 3 months after a slight subsidence and retroversion. No stem was revised or considered loose as measured with RSA. Conclusions: Washing the bone bed with jet-lavage prior to insertion of cementless stems does not affect the stability of cementless femoral components. No adverse effects were observed.
- Subjects :
- Adult
Male
medicine.medical_specialty
Time Factors
medicine.medical_treatment
Arthroplasty, Replacement, Hip
Prosthesis Design
Radiostereometric Analysis
Prosthesis
Osteoarthritis, Hip
03 medical and health sciences
0302 clinical medicine
medicine
Humans
Orthopedics and Sports Medicine
Animal study
Femur
Therapeutic Irrigation
Aged
Titanium
030222 orthopedics
Primary osteoarthritis
business.industry
Femoral canal
030206 dentistry
Middle Aged
equipment and supplies
Surgery
Hip arthroplasty
medicine.anatomical_structure
Treatment Outcome
Orthopedic surgery
Female
Hip Prosthesis
business
Follow-Up Studies
Subjects
Details
- ISSN :
- 17246067
- Volume :
- 30
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Hip international : the journal of clinical and experimental research on hip pathology and therapy
- Accession number :
- edsair.doi.dedup.....1c692534a6bf1e66ade45972630de8a4