Back to Search Start Over

Highly IR-transparent microfluidic chip with surface-modified BaF2 optical windows for Infrared Microspectroscopy of living cells

Authors :
Gianluca Grenci
Elisa Mitri
Giovanna Coceano
Dan Cojoc
Alessandro Pozzato
Massimo Tormen
Lisa Vaccari
Mitri, Elisa
Alessandro, Pozzato
Giovanna, Coceano
Dan, Cojoc
Lisa, Vaccari
Massimo, Tormen
Gianluca, Grenci
Source :
Microelectronic engineering 107 (2013): 6–9. doi:10.1016/j.mee.2013.02.068, info:cnr-pdr/source/autori:Mitri, E; Pozzato, A; Coceano, G; Cojoc, D; Vaccari, L; Tormen, M; Grenci, G/titolo:Highly IR-transparent microfluidic chip with surface-modified BaF2 optical windows for Infrared Microspectroscopy of living cells/doi:10.1016%2Fj.mee.2013.02.068/rivista:Microelectronic engineering/anno:2013/pagina_da:6/pagina_a:9/intervallo_pagine:6–9/volume:107
Publication Year :
2013
Publisher :
Elsevier BV, 2013.

Abstract

In this contribution we present the first example of a microfiuidic chip based on BaF2 for Infrared Microspectroscopy (IBMS) of living cells. The advantage in using barium fluoride as platform relies on its high IR transparency, especially in the spectral region below 1300 cm(-1), where the absorption bands of nucleic acids and carbohydrates are located. Barium fluoride is slightly soluble in water (0.12 g/100 g water) and it is potentially harmful for living cells. To overcome these problems, here we exploit an approach whose feasibility has been demonstrated previously on CaF2: the surface modification obtained by sputtering a thin Si layer on the surface. The Surface Modified Microfluidic Devices (SM-MD) hence obtained not only solve the BaF2 drawbacks, but also provide a silicon-like substrate fully compatible with standard micro-fabrication processes. These potentialities are here further explored in the direction of chemical or topographical nano-patterning of the silicon-like surface. The silicon thin layer was structured in the shape of 300 nm wide grooves (500 nm pitch) with a thickness of 35 nm by using standard NIL and etching processes; chemical patterning was achieved by exploiting silane chemistry. Finally, we tested the performances of these devices at SISSI beamline@Elettra, collecting IR spectra of single MDA-MB-231 living cells maintained either in physiological solution or complete medium. A comparison of the spectra of a single cell obtained in BaF2 and CaF2 MDs is reported. (C) 2013 Elsevier B.V. All rights reserved.

Details

ISSN :
01679317
Volume :
107
Database :
OpenAIRE
Journal :
Microelectronic Engineering
Accession number :
edsair.doi.dedup.....1c94d561a72958ffc201c0ce62e28c41
Full Text :
https://doi.org/10.1016/j.mee.2013.02.068