A novel nitrite biosensor based on conductometric electrode modified with cytochrome c nitrite reductase composite membrane
- Source :
- Biosensorsbioelectronics. 24(6)
- Publication Year :
- 2008
-
Abstract
- A conductometric biosensor for nitrite detection was developed using cytochrome c nitrite reductase (ccNiR) extracted from Desulfovibrio desulfuricans ATCC 27774 cells immobilized on a planar interdigitated electrode by cross-linking with saturated glutaraldehyde (GA) vapour in the presence of bovine serum albumin, methyl viologen (MV), Nafion, and glycerol. The configuration parameters for this biosensor, including the enzyme concentration, ccNiR/BSA ratio, MV concentration, and Nafion concentration, were optimized. Various experimental parameters, such as sodium dithionite added, working buffer solution, and temperature, were investigated with regard to their effect on the conductance response of the biosensor to nitrite. Under the optimum conditions at room temperature (about 25 degrees C), the conductometric biosensor showed a fast response to nitrite (about 10s) with a linear range of 0.2-120 microM, a sensitivity of 0.194 microS/microM [NO(2)(-)], and a detection limit of 0.05 microM. The biosensor also showed satisfactory reproducibility (relative standard deviation of 6%, n=5). The apparent Michaelis-Menten constant (K(M,app)) was 338 microM. When stored in potassium phosphate buffer (100mM, pH 7.6) at 4 degrees C, the biosensor showed good stability over 1 month. No obvious interference from other ionic species familiar in natural waters was detected. The application experiments show that the biosensor is suitable for use in real water samples.
- Subjects :
- Conductometry
Inorganic chemistry
Biomedical Engineering
Biophysics
Cytochromes c1
macromolecular substances
Biosensing Techniques
Sensitivity and Specificity
Sodium dithionite
chemistry.chemical_compound
Nitrate Reductases
Nafion
Cytochromes a1
Electrochemistry
Nitrite
Cytochrome c nitrite reductase
Electrodes
Nitrites
Detection limit
technology, industry, and agriculture
Electric Conductivity
Reproducibility of Results
General Medicine
Buffer solution
Equipment Design
Enzymes, Immobilized
Equipment Failure Analysis
chemistry
Biosensor
Water Pollutants, Chemical
Biotechnology
Nuclear chemistry
Subjects
Details
- ISSN :
- 18734235
- Volume :
- 24
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- Biosensorsbioelectronics
- Accession number :
- edsair.doi.dedup.....1dc8acdb188acb9cd4141b26c23e26df