OBJETIVOS: Realizar normatização do PEV-PR e analisar influência de, técnica, ângulo visual (AV), e variáveis biológicas, sexo, idade e diferença interocular. METODOLOGIA: 60 voluntários saudáveis divididos em sexo e idade (entre 20-61 anos) foram submetidos a PEV-PR, em cada olho, utilizando dois AV, 14 e 28 min. Foram avaliadas latências das ondas N75, P100 e N120. RESULTADOS:Valor médio de latência (ms) com AV de 14 e 28 min foi respectivamente: 78,2 e 74,3 (N75); 102,3 e 98,8 (P100); 136,7 e 130,5 (N120). Valor N75 foi igual nos dois sexos; P100 maior em homens que em mulheres apenas para AV de 14 min, e N120 maior em homens nos dois tamanhos de AV. Idade e a diferença interocular não mostraram diferenças significativas. CONCLUSÕES:Neste estudo foram observados valores maiores de latência do PEV-PR com AV de 14 min do que 28 min, sendo que o sexo masculino apresentou valores maiores em apenas algumas latências e AV. OBJECTIVE: To obtain reference values for PR-VEP and to analyze influence of technical parameters, visual angle (VA), and biological factors, gender, age and interocular latencies differences. METHODS: 60 volunteers (30 male/30 female), divided in three age groups (20-61 years), were submitted to PR-VEP, which was done separately in each eye with two VA, 14 and 28. We analyzed the following latency values: N75, P100 and N120. RESULTS: Mean latencies (msec) with 14 and 28 min were respectively: 78.2 and 74.3 (N75); 102.3 and 98.8 (P100); 136.7 and 130.4 (N120). N75 was similar in both sexes; P100 longer in men only for 14 min; N120 was longer in men in both sizes. The age studied, between 20-61 years, did not influence on the results for both VA. There was no significance for interocular differences. CONCLUSIONS: In this study PR-VEP showed longer values with VA 14 than 28, and men had longer values for some latencies and check sizes.

Details

Language :
Portuguese
Database :
OpenAIRE
Journal :
Journal of Epilepsy and Clinical Neurophysiology, Volume: 11, Issue: 4, Pages: 171-175, Published: DEC 2005, Journal of Epilepsy and Clinical Neurophysiology v.11 n.4 2005, Journal of epilepsy and clinical neurophysiology, Liga Brasileira de Epilepsia (LBE), instacron:LBE
Accession number :
edsair.doi.dedup.....1e55491897b75c3ce652c0157d5d367c