Back to Search
Start Over
Interobserver and interquipment variability of echo-doppler examination of the portal vein: Effect of a cooperative training program
- Source :
- Hepatology. 21:428-433
- Publication Year :
- 1995
- Publisher :
- Ovid Technologies (Wolters Kluwer Health), 1995.
-
Abstract
- The aim of this study was to assess the interobserver, interequipment, and time-dependent variabilities of echo-Doppler measurements of portal blood flow velocity (PBV), portal vein diameters (PVDs) and their derived parameters, portal blood flow (PBF), and congestion index (CI) in cirrhotic patients. The influence of a cooperative training program of the operators on the reproductibility of the results was also investigated. The echo-Doppler parameters were independently measured in 15 patients by four skilled operators, using four echo-Doppler machines (Acuson, ATL, Hitachi-Esaote, Toshiba. Eight of the 15 patients were restudied after 15 days by the same operators using only one machine. Significantly different values of PBV, PBF, and CI were obtained. PBV variance was equipment-related (32%) and operator-related in a smaller portion (5%). No systematic effect related to the time of investigation was found. After training to define a precise protocol, new measurements were performed by four operators on 8 different patients. No significant differences were found among the operators for any of the parameters and the 95% confidence limits (CL) and coefficients of variation (CV) of PBV showed a marked decrease (CL from +/- 26.4% to +/- 15.6%). These results indicate that (1) a significant systematic variability exists between Doppler measurements with different equipment; (2) there is no significant time-dependent systematic variability of Doppler measurements; and (3) a cooperative training program reduces the interobserver variability for direct measurements, such as PBV.
- Subjects :
- Liver Cirrhosis
medicine.medical_specialty
Time Factors
Health Personnel
Portal vein
ecografia doppler
ipertensione portale
cirrosi epatica
Hemodynamics
Doppler measurements
Clinical Protocols
medicine
Humans
Echo doppler
Observer Variation
Analysis of Variance
Hepatology
Portal Vein
business.industry
Reproducibility of Results
Ultrasonography, Doppler
Blood flow
Confidence interval
Surgery
Portal blood
Training program
business
Nuclear medicine
Blood Flow Velocity
Program Evaluation
Subjects
Details
- ISSN :
- 15273350 and 02709139
- Volume :
- 21
- Database :
- OpenAIRE
- Journal :
- Hepatology
- Accession number :
- edsair.doi.dedup.....1eac6b4a6574b27aaef31936895de3ba
- Full Text :
- https://doi.org/10.1002/hep.1840210225