Clinical review: Consensus recommendations on measurement of blood glucose and reporting glycemic control in critically ill adults

Authors :
Mikhail Kosiborod
James S. Krinsley
Jeffrey I. Joseph
Mitchell G. Scott
Dieter Mesotten
Greet Van den Berghe
Thomas Desaive
Roman Hovorka
Jean-Charles Preiser
Jan Wernerman
Robbert J. Slingerland
Iain MacKenzie
Simon Finfer
Tom Van Herpe
Tony Cass
Marcus J. Schultz
Source :
Critical Care, Critical care, 17 (3
Publication Year :
2013

Abstract

The management reporting and assessment of glycemic control lacks standardization. The use of different methods to measure the blood glucose concentration and to report the performance of insulin treatment yields major disparities and complicates the interpretation and comparison of clinical trials. We convened a meeting of 16 experts plus invited observers from industry to discuss and where possible reach consensus on the most appropriate methods to measure and monitor blood glucose in critically ill patients and on how glycemic control should be assessed and reported. Where consensus could not be reached, recommendations on further research and data needed to reach consensus in the future were suggested. Recognizing their clear conflict of interest, industry observers played no role in developing the consensus or recommendations from the meeting. Consensus recommendations were agreed for the measurement and reporting of glycemic control in clinical trials and for the measurement of blood glucose in clinical practice. Recommendations covered the following areas: How should we measure and report glucose control when intermittent blood glucose measurements are used? What are the appropriate performance standards for intermittent blood glucose monitors in the ICU? Continuous or automated intermittent glucose monitoring - methods and technology: can we use the same measures for assessment of glucose control with continuous and intermittent monitoring? What is acceptable performance for continuous glucose monitoring systems? If implemented, these recommendations have the potential to minimize the discrepancies in the conduct and reporting of clinical trials and to improve glucose control in clinical practice. Furthermore, to be fit for use, glucose meters and continuous monitoring systems must match their performance to fit the needs of patients and clinicians in the intensive care setting.<br />JOURNAL ARTICLE<br />SCOPUS: re.j<br />info:eu-repo/semantics/published

Details

Language :
English
ISSN :
13648535
Volume :
17
Issue :
3
Database :
OpenAIRE
Journal :
Critical care (London, England)
Accession number :
edsair.doi.dedup.....2059a4b740aed9dac727f5a5617e3fbd
Full Text :
https://doi.org/10.1186/cc12537