Back to Search
Start Over
Left ventricular non-compaction as a potential source for cryptogenic ischemic stroke in the young: A case-control study
- Source :
- PLoS ONE, Vol 15, Iss 8, p e0237228 (2020), PLoS ONE
- Publication Year :
- 2020
- Publisher :
- Public Library of Science (PLoS), 2020.
-
Abstract
- Background Up to 50% of ischemic strokes in the young after thorough diagnostic work-up remain cryptogenic or associated with low-risk sources of cardioembolism such as patent foramen ovale (PFO). We studied with cardiac magnetic resonance (CMR) imaging, whether left ventricular (LV) non-compaction-a possible source for embolic stroke due to sluggish blood flow in deep intertrabecular recesses-is associated with cryptogenic strokes in the young. Methods Searching for Explanations for Cryptogenic Stroke in the Young: Revealing the Etiology, Triggers, and Outcome (SECRETO; NCT01934725) is an international prospective multicenter case-control study of young adults (aged 18-49 years) presenting with an imaging-positive first-ever ischemic stroke of undetermined etiology. In this pilot substudy, 30 cases and 30 age- and sex-matched stroke-free controls were examined with CMR. Transcranial Doppler (TCD) bubble test was performed to evaluate the presence and magnitude of right-to-left shunt (RLS). Results There were no significant differences in LV volumes, masses or systolic function between cases and controls; none of the participants had non-compaction cardiomyopathy. Semi-automated assessment of LV non-compaction was highly reproducible. Non-compacted LV mass (median 14.0 [interquartile range 12.6-16.0] g/m2 vs. 12.7 [10.4-16.6] g/m2, p = 0.045), the ratio of non-compacted to compacted LV mass (mean 25.6 ± 4.2% vs. 22.8 ± 6.0%, p = 0.015) and the percentage of non-compacted LV volume (mean 17.6 ± 2.9% vs. 15.7 ± 3.8%, p = 0.004) were higher in cases compared to controls. In a multivariate conditional logistic regression model including non-compacted LV volume, RLS and body mass index, the percentage of non-compacted LV volume (odds ratio [OR] 1.55, 95% confidence interval [CI] 1.10-2.18, p = 0.011) and the presence of RLS (OR 11.94, 95% CI 1.14-124.94, p = 0.038) were independently associated with cryptogenic ischemic stroke. Conclusions LV non-compaction is associated with a heightened risk of cryptogenic ischemic stroke in young adults, independent of concomitant RLS and in the absence of cardiomyopathy. Clinical trial registration SECRETO; NCT01934725. Registered 4th September 2013. https://clinicaltrials.gov/ct2/show/NCT01934725.
- Subjects :
- Ultrasonography, Doppler, Transcranial
Cardiomyopathy
030204 cardiovascular system & hematology
Cardiovascular Medicine
Vascular Medicine
DISEASE
030218 nuclear medicine & medical imaging
Diagnostic Radiology
Brain Ischemia
0302 clinical medicine
Medical Conditions
Interquartile range
Medicine and Health Sciences
Magnetic Resonance
Young adult
2. Zero hunger
Multidisciplinary
Physics
Radiology and Imaging
Magnetism
TRIGGERS
Middle Aged
Condensed Matter Physics
Magnetic Resonance Imaging
3. Good health
ETIOLOGY
Stroke
Neurology
Research Design
Cardiovascular Diseases
Physical Sciences
Cardiology
NONCOMPACTION
Medicine
Female
Cardiomyopathies
Research Article
Adult
medicine.medical_specialty
Adolescent
Imaging Techniques
Cerebrovascular Diseases
Heart Ventricles
Science
Research and Analysis Methods
DIAGNOSIS
03 medical and health sciences
Young Adult
Diagnostic Medicine
Internal medicine
EXPLANATIONS
medicine
Adults
Humans
Ischemic Stroke
business.industry
Odds ratio
Cardiovascular Disease Risk
medicine.disease
3126 Surgery, anesthesiology, intensive care, radiology
Confidence interval
Transcranial Doppler
Young Adults
Age Groups
Case-Control Studies
3121 General medicine, internal medicine and other clinical medicine
People and Places
Patent foramen ovale
Population Groupings
HYPERTRABECULATION/NONCOMPACTION
business
Body mass index
Subjects
Details
- Language :
- English
- ISSN :
- 19326203
- Volume :
- 15
- Issue :
- 8
- Database :
- OpenAIRE
- Journal :
- PLoS ONE
- Accession number :
- edsair.doi.dedup.....22da40dc0533e0be7fd0b6e936400d22