Back to Search
Start Over
Feasibility and Validity of a Graded One-Legged Cycle Exercise Test to Determine Peak Aerobic Capacity in Older People With a Lower-Limb Amputation
- Source :
- Physical Therapy, 92(2), 329-338. Oxford University Press, Wezenberg, D, de Haan, A, van der Woude, L H V & Houdijk, J H P 2012, ' Feasibility and Validity of a Graded One-Legged Cycle Exercise Test to Determine Peak Aerobic Capacity in Older People With a Lower-Limb Amputation ', Physical Therapy, vol. 92, no. 2, pp. 329-338 . https://doi.org/10.2522/ptj.20110125, Physical Therapy, 92(2), 329-338. American Physical Therapy Association
- Publication Year :
- 2012
-
Abstract
- BackgroundInformation concerning exercise tolerance and aerobic capacity is imperative for generating effective and safe exercise programs. However, for older people with a lower-limb amputation, a standard exercise test is not available.ObjectiveThe primary aim of the present study was to determine whether a graded 1-legged peak exercise test is feasible and provides a valid assessment of peak aerobic capacity in older people walking with a lower-limb prosthesis.DesignThis was a quasi-experimental case-control study.MethodsA total of 36 older people with a lower-limb prosthesis and 21 people who were able-bodied (controls) (overall mean age=61.7 years, SD=6.1) performed a discontinuous graded 1-legged exercise test. The peak respiratory exchange ratio was used as an indicator of maximal effort. The controls performed an additional 2-legged exercise test to provide insight into differences between the testing modes.ResultsAll participants were able to perform the exercise test. Electrocardiographic tracings and blood pressure were adequately monitored. The controls and the people with a lower-limb amputation were able to stress the cardiovascular system to a similar extent. Analyses of construct validity revealed that the peak aerobic capacity measured with the 1-legged exercise test was able to distinguish between participants on the basis of age, body mass index, and sex to a similar extent as the conventional 2-legged exercise test.LimitationsThe results can be generalized only to people who are able to ambulate with their prosthesis.ConclusionsThe graded 1-legged exercise test was feasible and provided a valid assessment of peak aerobic capacity and exercise tolerance in older people walking with a lower-limb prosthesis.
- Subjects :
- Male
medicine.medical_specialty
DYSVASCULAR AMPUTATION
medicine.medical_treatment
Physical fitness
Artificial Limbs
Physical Therapy, Sports Therapy and Rehabilitation
PHYSICAL-FITNESS
Amputation, Surgical
DISEASE
Electrocardiography
Oxygen Consumption
Physical medicine and rehabilitation
APPROPRIATE
SDG 3 - Good Health and Well-being
medicine
Humans
Respiratory exchange ratio
Aerobic capacity
Leg
Chi-Square Distribution
Exercise Tolerance
ANAEROBIC THRESHOLD
business.industry
Construct validity
Middle Aged
EFFICACY
Test (assessment)
AMPUTEES
Amputation
Case-Control Studies
Exercise Test
Physical therapy
Feasibility Studies
Female
OXYGEN-UPTAKE
ARM ERGOMETRY
business
Anaerobic exercise
Chi-squared distribution
RESPONSES
Subjects
Details
- Language :
- English
- ISSN :
- 00319023
- Volume :
- 92
- Issue :
- 2
- Database :
- OpenAIRE
- Journal :
- Physical Therapy
- Accession number :
- edsair.doi.dedup.....23d0de93f13dea3d48f7681da56d2e58
- Full Text :
- https://doi.org/10.2522/ptj.20110125