Back to Search Start Over

Direct advection measurements do not help to solve the night-time CO2 closure problem : evidence from three different forests

Authors :
Marc Aubinet
Elisa Canepa
Christian Feigenwinter
Pavel Sedlák
E. van Gorsel
Leonardo Montagnani
Anders Lindroth
Corinna Rebmann
Bernard Heinesch
C. Bernhofer
Source :
Agricultural and forest meteorology, 150 (2010): 655–664. doi:10.1016/j.agrformet.2010.01.016, info:cnr-pdr/source/autori:Aubinet M.; Feigenwinter C.; Heinesch B.; Bernhofer C.; Canepa E.; Lindroth A.; Montagnani L.; Rebmann C.; Sedlak P.; Van Gorsel E./titolo:Direct advection measurements do not help to solve the night-time CO2 closure problem: Evidence from three different forests/doi:10.1016%2Fj.agrformet.2010.01.016/rivista:Agricultural and forest meteorology (Print)/anno:2010/pagina_da:655/pagina_a:664/intervallo_pagine:655–664/volume:150
Publication Year :
2010
Publisher :
Elsevier, 2010.

Abstract

The ADVEX project involved conducting extensive advection measurements at three sites, each with a different topography. One goal of the project was to measure the [CO2] balance under night-time conditions, in an attempt to improve NEE estimates. Four towers were arranged in a square around a main tower, with the sides of the square about 100 m long. Equipped with 16 sonic anemometers and [CO2] sampling points, the towers were installed to measure vertical and horizontal advection of [CO2]. Vertical turbulent fluxes were measured by an eddy covariance system at the top of the main tower. The results showed that horizontal advection varied greatly from site to site and from one wind sector to another, the highest values being reached when there were large friction velocities and fairly unstable conditions. There was less variation in vertical advection, the highest values being reached when there were low friction velocities and stable conditions. The night-time NEE estimates deduced from the mass balance were found to be incompatible with biologically driven fluxes because (i) they varied strongly from one wind sector to another and this variation could not be explained in terms of a response of the biologic flux to climate, (ii) their order of magnitude was not realistic and (iii) they still showed a trend vs. friction velocity. From a critical analysis of the measurement and data treatment we concluded that the causes of the problem are related to the representativeness of the measurement (control volume size, sampling resolution) or the hypotheses underlying the derivation of the [CO2] mass balance (ignoring the horizontal turbulent flux divergence). This suggests that the improvement of eddy flux measurements by developing an advection completed [CO2] mass balance at night would be practically difficult. (C) 2010 Elsevier B.V. All rights reserved. (Less)

Details

Database :
OpenAIRE
Journal :
Agricultural and forest meteorology, 150 (2010): 655–664. doi:10.1016/j.agrformet.2010.01.016, info:cnr-pdr/source/autori:Aubinet M.; Feigenwinter C.; Heinesch B.; Bernhofer C.; Canepa E.; Lindroth A.; Montagnani L.; Rebmann C.; Sedlak P.; Van Gorsel E./titolo:Direct advection measurements do not help to solve the night-time CO2 closure problem: Evidence from three different forests/doi:10.1016%2Fj.agrformet.2010.01.016/rivista:Agricultural and forest meteorology (Print)/anno:2010/pagina_da:655/pagina_a:664/intervallo_pagine:655–664/volume:150
Accession number :
edsair.doi.dedup.....270cb2647e3f0dc028577e040e8c50c9
Full Text :
https://doi.org/10.5451/unibas-ep12677