Back to Search Start Over

Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR‐only breast radiotherapy

Authors :
Maria A. Thomas
Vivian Rodriguez
Imran Zoberi
Olga Green
Sasa Mutic
Hao Zhang
William R. Kennedy
Sven Olberg
Justin C. Park
Jaehee Chun
Jin Sung Kim
Source :
Medical Physics. 46:4135-4147
Publication Year :
2019
Publisher :
Wiley, 2019.

Abstract

Purpose The superior soft-tissue contrast achieved using magnetic resonance imaging (MRI) compared to x-ray computed tomography (CT) has led to the popularization of MRI-guided radiation therapy (MR-IGRT), especially in recent years with the advent of first and second generation MRI-based therapy delivery systems for MR-IGRT. The expanding use of these systems is driving interest in MRI-only RT workflows in which MRI is the sole imaging modality used for treatment planning and dose calculations. To enable such a workflow, synthetic CT (sCT) data must be generated based on a patient's MRI data so that dose calculations may be performed using the electron density information derived from CT images. In this study, we propose a novel deep spatial pyramid convolutional framework for the MRI-to-CT image-to-image translation task and compare its performance to the well established U-Net architecture in a generative adversarial network (GAN) framework. Methods Our proposed framework utilizes atrous convolution in a method named atrous spatial pyramid pooling (ASPP) to significantly reduce the total number of parameters required to describe the model while effectively capturing rich, multi-scale structural information in a manner that is not possible in the conventional framework. The proposed framework consists of a generative model composed of stacked encoders and decoders separated by the ASPP module, where atrous convolution is applied at increasing rates in parallel to encode large-scale features. The performance of the proposed method is compared to that of the conventional GAN framework in terms of the time required to train the model and the image quality of the generated sCT as measured by the root mean square error (RMSE), structural similarity index (SSIM), and peak signal-to-noise ratio (PSNR) depending on the size of the training data set. Dose calculations based on sCT data generated using the proposed architecture are also compared to clinical plans to evaluate the dosimetric accuracy of the method. Results Significant reductions in training time and improvements in image quality are observed at every training data set size when the proposed framework is adopted instead of the conventional framework. Over 1042 test images, values of 17.7 ± 4.3 HU, 0.9995 ± 0.0003, and 71.7 ± 2.3 are observed for the RMSE, SSIM, and PSNR metrics, respectively. Dose distributions calculated based on sCT data generated using the proposed framework demonstrate passing rates equal to or greater than 98% using the 3D gamma index with a 2%/2 mm criterion. Conclusions The deep spatial pyramid convolutional framework proposed here demonstrates improved performance compared to the conventional GAN framework that has been applied to the image-to-image translation task of sCT generation. Adopting the method is a first step toward an MRI-only RT workflow that enables widespread clinical applications for MR-IGRT including online adaptive therapy.

Details

ISSN :
24734209 and 00942405
Volume :
46
Database :
OpenAIRE
Journal :
Medical Physics
Accession number :
edsair.doi.dedup.....280e63beafbe3831aaf512ecedec5b28
Full Text :
https://doi.org/10.1002/mp.13716