Back to Search
Start Over
Tomographic Measurement of Gutters and Analysis of the Conformability of Stent Grafts in the Octopus Technique for Endovascular Thoracoabdominal Aneurysm Repair
- Source :
- Annals of Vascular Surgery. 33:202-209
- Publication Year :
- 2016
- Publisher :
- Elsevier BV, 2016.
-
Abstract
- Background The Octopus technique is an off-label and off-the-shelf strategy used as an option in the management of some specific and selected cases of thoracoabdominal aortic aneurysms (TAAA). We sought to compare 2 different methods of measurements on computed tomography (CT) slices and to evaluate the accommodation and conformability, before and after ballooning, of the components used in the Octopus technique. Methods The CT gutter analysis between the 3 stent grafts within the short docking limb of the Excluder ® was made using Viabahns ® of 8, 7, and 6 mm in diameter. Each of the 10 possible combinations underwent a CT established protocol. The best axial image of the docking limb was submitted for an evaluation by 2 independent analysts, using 2 different methods. We also performed a postballooning evaluation, and the same CT protocol was used. Results There was no significant difference between the formats of measurement type “A” and type “B.” Furthermore, there was no significant difference between the measurements made by the independent analysts. The tomography analyses demonstrated that the combination of stent grafts (Viabahn) of 8 and 7 mm diameter, inside the short docking limb of the bifurcated endoprosthesis, had the best possible relationship between the diameters used. These combinations showed better conformability and juxtaposition, with smaller areas of gutters and theoretically less possibility of endoleak. In addition, we found that postimplant balloon dilatation impaired the conformability and juxtaposition of the stent grafts (Viabahn) in the optimum combinations. Conclusions In this analysis, we demonstrated a feasible, reliable, and reproducible form of CT measurement of the gutters in the Octopus technique for endovascular repair of TAAAs. Based on these measurements, there is a preferable combination of Viabahn sizes to be used in the Octopus technique and that postdilatation impairs the conformability and juxtaposition.
- Subjects :
- medicine.medical_specialty
Aortography
Computed Tomography Angiography
medicine.medical_treatment
030204 cardiovascular system & hematology
Prosthesis Design
Thoracoabdominal Aortic Aneurysms
Blood Vessel Prosthesis Implantation
03 medical and health sciences
Aortic aneurysm
0302 clinical medicine
Predictive Value of Tests
Blood vessel prosthesis
Multidetector Computed Tomography
medicine
Humans
030212 general & internal medicine
Thoracoabdominal aneurysm
Computed tomography angiography
Observer Variation
Aortic Aneurysm, Thoracic
medicine.diagnostic_test
business.industry
Endovascular Procedures
Reproducibility of Results
Stent
General Medicine
medicine.disease
Blood Vessel Prosthesis
Feasibility Studies
Stents
Surgery
Radiology
Tomography
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 08905096
- Volume :
- 33
- Database :
- OpenAIRE
- Journal :
- Annals of Vascular Surgery
- Accession number :
- edsair.doi.dedup.....2821f0bde7bad4bc7053372cb4b1f314
- Full Text :
- https://doi.org/10.1016/j.avsg.2015.11.030