Back to Search
Start Over
Accuracy in Obtaining 100 μg from 10 mg of Morphine for Spinal Anesthesia
- Source :
- Obstetric Anesthesia Digest. 36:162-162
- Publication Year :
- 2016
- Publisher :
- Ovid Technologies (Wolters Kluwer Health), 2016.
-
Abstract
- Study objective Dilution is often required to obtain appropriate concentrations of intrathecal morphine for analgesia. We compared techniques of diluting by measuring the quantity of morphine actually obtained in the final solution. Design This is an experimental study by 3 experienced anesthesiologists. Setting The setting is at a university teaching hospital. Patients There are no patients. Interventions There are no interventions. Measurements Five techniques for obtaining 100 μg from 10 mg/mL were compared: technique 1 (T1) = extraction up to 0.1 graduation on a 1-mL syringe, followed by simple dilution (SD). Technique 2 (T2) = As for T1 but syringe was shaken to mix solution. Technique 3 (T3): SD with 10-mL syringe. Technique 4 (T4): Double dilution with 10-mL syringe. Technique 5 (T5): Extraction up to the 0.1 graduation of a 1-mL syringe, then SD, then shake solution by hand. Three tests using high-performance liquid chromatography with ultraviolet were performed on each syringe prepared 3 consecutive times, namely, at the first (beginning, B), fifth (middle, M) and last (end, E) milliliter or 0.1 mL (depending on syringe type). Main results Average overall concentrations were 208 ±19, 199 ±24, 120 ±13, 136 ±9, and 119 ±16 μg/0.1 mL, T1-T5, respectively. By Kruskal-Wallis test, we classified the techniques according to the magnitude of the difference between the observed concentration of morphine and the desired (theoretical) concentration of 100 μg/0.1 mL. In ascending order, techniques ranked as follows: T5 (smallest difference), T3, T4, T2, and T1 (greatest difference) ( P = .0001). Conclusions There is significant variability in the concentration of morphine actually contained in final solutions after dilution. Morphine presented in different premixed concentrations increases the risk of error. We advocate technique 5 as described above, whereas technique 1 should be prohibited.
- Subjects :
- medicine.medical_specialty
Morphine
business.industry
Drug Compounding
Syringes
Spinal anesthesia
Liter
Anesthesia, Spinal
Intrathecal morphine
Dilution
Surgery
Analgesics, Opioid
Hospitals, University
Anesthesiology and Pain Medicine
Anesthesiology
Anesthesia
medicine
Humans
University teaching
business
Chromatography, High Pressure Liquid
Injections, Spinal
Syringe
medicine.drug
Subjects
Details
- ISSN :
- 0275665X
- Volume :
- 36
- Database :
- OpenAIRE
- Journal :
- Obstetric Anesthesia Digest
- Accession number :
- edsair.doi.dedup.....28722d74df4ad30e39612b9197aa18d2