Back to Search
Start Over
Reliability of 31P-magnetic resonance spectroscopy during an exhaustive incremental exercise test in children
- Source :
- European Journal of Applied Physiology. 98:556-565
- Publication Year :
- 2006
- Publisher :
- Springer Science and Business Media LLC, 2006.
-
Abstract
- This study examined the reliability of (31)P-magnetic resonance spectroscopy (MRS) to measure parameters of muscle metabolic function in children. On separate days, 14 children (7 boys and 7 girls) completed three knee-extensor incremental tests to exhaustion inside a whole-body scanner (1.5 T, Phillips). The dynamic changes in the ratio of inorganic phosphate to phosphocreatine (Pi/PCr) and intracellular muscle pH were resolved every 30 s. Using plots of Pi/PCr and pH against power output (W), intracellular thresholds (ITs) for each variable were determined using both subjective and objective procedures. The IT(Pi/PCr) and IT(pH) were observed subjectively in 93 and 81% of their respective plots, whereas the objective method identified the IT(Pi/PCr) in 88% of the plots. The IT(pH) was undetectable using the objective method. End exercise (END) END(Pi/PCr), END(pH), IT(Pi/PCr) and IT(pH) were examined using typical error statistics expressed as a % coefficient of variation (CV) across all three exercise tests. The CVs for the power output at the subjectively determined IT(Pi/PCr) and IT(pH) were 10.6 and 10.3%, respectively. Objective identification of the IT(Pi/PCr) had a CV of 16.3%. CVs for END(pH) and END(Pi/PCr) were 0.9 and 50.0%, respectively. MRS provides a valuable window into metabolic changes during exercise in children. During knee-extensor exercise to exhaustion, END(pH) and the subjectively determined IT(Pi/PCr) and IT(pH) demonstrate good reliability and thus stable measures for the future study of developmental metabolism. However, the objectively determined IT(Pi/PCr) and END(Pi/PCr) displayed poor reliability.
- Subjects :
- Male
Magnetic Resonance Spectroscopy
Phosphocreatine
Physiology
Coefficient of variation
Physical exercise
Phosphates
Quadriceps Muscle
Incremental exercise
chemistry.chemical_compound
Nuclear magnetic resonance
Inorganic phosphate
Physiology (medical)
Humans
Medicine
Knee
Orthopedics and Sports Medicine
Power output
Child
Muscle, Skeletal
Reliability (statistics)
business.industry
Public Health, Environmental and Occupational Health
Reproducibility of Results
Objective method
General Medicine
Hydrogen-Ion Concentration
chemistry
Exercise Test
Physical Endurance
Female
business
Nuclear medicine
Subjects
Details
- ISSN :
- 14396327 and 14396319
- Volume :
- 98
- Database :
- OpenAIRE
- Journal :
- European Journal of Applied Physiology
- Accession number :
- edsair.doi.dedup.....2b577c8a585122069e48611d23a17895
- Full Text :
- https://doi.org/10.1007/s00421-006-0302-x