Back to Search
Start Over
Swan-Ganz Catheter Entrapment in Open Heart Surgery
- Source :
- Journal of Cardiac Surgery. 15:313-315
- Publication Year :
- 2000
- Publisher :
- Hindawi Limited, 2000.
-
Abstract
- Background and aim Swan-Ganz catheterization is an important technique for monitoring perioperative and postoperative cardiac pressures during open heart surgery. However, although a rare condition, resistance may be encountered while removing the catheter postoperatively and its removal must be accomplished through surgery. Methods Between May 1988 and February 2000, we observed Swan-Ganz catheter entrapment complications in 10 cases subjected to open heart surgery. All the cases had valve replacement. Five cases were male, while five were female. The Swan-Ganz catheter was retained in the vena cava cannulation suture in four cases, in the right atriotomy in three cases, in a left atriotomy suture in one case, and looped around the right ventricular papillary muscle in one case. In the last case, it was looped around chordae tendinea between the tricuspid valve conal papillary muscle and septal leaflet. Although cardiopulmonary bypass equipment was prepared, it was not utilized in any of the cases. The catheter was released and removed by placing a pursestring suture on the vena cava cannulation site in four cases, by placing a matrix suture on the proximal and distal part of the left or right atrial suture line and a purse-string suture on the site of the entrapment in four cases, and by digital palpation from the right atrial appendage in two cases. Results All patients were taken to the intensive care unit postoperatively and to the wards the next day without complications. Conclusions When performing open heart surgery, the surgeon should not leave the Swan-Ganz catheter in the suture while closing the right or left atriotomy or during venous cannulation. In addition, the catheter should be moved after suturing to ensure that there is no entrapment.
- Subjects :
- Male
Reoperation
Pulmonary and Respiratory Medicine
medicine.medical_specialty
medicine.medical_treatment
Heart Valve Diseases
Swan Ganz Catheter
law.invention
Valve replacement
Suture (anatomy)
law
medicine
Cardiopulmonary bypass
Humans
Intraoperative Complications
Papillary muscle
Device Removal
Heart Valve Prosthesis Implantation
Postoperative Care
Tricuspid valve
business.industry
Suture Techniques
Perioperative
Surgery
Catheter
medicine.anatomical_structure
Catheterization, Swan-Ganz
Anesthesia
cardiovascular system
Female
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 15408191 and 08860440
- Volume :
- 15
- Database :
- OpenAIRE
- Journal :
- Journal of Cardiac Surgery
- Accession number :