Back to Search
Start Over
Investigation of the role of infusate properties related to midline catheter failure in an ovine model
- Source :
- American Journal of Health-System Pharmacy: AJHP
- Publication Year :
- 2020
- Publisher :
- Oxford University Press, 2020.
-
Abstract
- Purpose Infusate osmolarity, pH, and cytotoxicity were investigated as risk factors for midline catheter failure. Methods An experimental, randomized, controlled, blinded trial was conducted using an ovine model. Two 10-cm, 18-gauge single-lumen midline catheters were inserted into the cephalic veins of sheep. The animals were divided into 6 study arms and were administered solutions of vancomycin 4 mg/mL (a low-cytotoxicity infusate) or 10 mg/mL (a high-cytotoxicity infusate), doxycycline 1 mg/mL (an acidic infusate), or acyclovir 3.5 mg/mL (an alkaline infusate) and 0.9% sodium chloride injection; or 1 of 2 premixed Clinimix (amino acids in dextrose; Baxter International) products with respective osmolarities of 675 mOsm/L (a low-osmolarity infusate) and 930 mOsm/L (a mid-osmolarity infusate). Contralateral legs were infused with 0.9% sodium chloride injection for control purposes. Catheter failure was evaluated by assessment of adverse clinical symptoms (swelling, pain, leakage, and occlusion). A quantitative vessel injury score (VIS) was calculated by grading 4 histopathological features: inflammation, mural thrombus, necrosis, and perivascular reaction. Results Among 20 sheep included in the study, the overall catheter failure rate was 95% for test catheters (median time to failure, 7.5 days; range, 3–14 days), while 60% of the control catheters failed before or concurrently (median time to failure, 7 days; range, 4.5–14 days). Four of the 6 study arms (all but the Clinimix 675-mOsm/L and acyclovir 3.5-mg/mL arms) demonstrated an increase in mean VIS of ≥77% in test vs control legs (P ≤ 0.034). Both pain and swelling occurred at higher rates in test vs control legs: 65% vs 10% and 70% vs 50%, respectively. The mean difference in rates of occlusive pericatheter mural thrombus between the test and control arms was statistically significant for the vancomycin 10-mg/mL (P = 0.0476), Clinimix 930-mOsm/L (P = 0.0406), and doxycycline 1-mg/mL (P = 0.032) arms. Conclusion Administration of infusates of varied pH, osmolarity, and cytotoxicity via midline catheter resulted in severe vascular injury and premature catheter failure; therefore, the tested infusates should not be infused via midline catheters.
- Subjects :
- Male
Necrosis
Time Factors
Pain
midline catheters
030204 cardiovascular system & hematology
Sodium Chloride
03 medical and health sciences
0302 clinical medicine
Catheters, Indwelling
Anti-Infective Agents
Risk Factors
Occlusion
medicine
Animals
030212 general & internal medicine
Amino Acids
osmolarity
Median time to failure
Pharmacology
Osmole
Doxycycline
Sheep
Osmotic concentration
business.industry
pH
Health Policy
Osmolar Concentration
Clinical Research Report
Hydrogen-Ion Concentration
Catheter
Anesthesia
Vancomycin
AcademicSubjects/MED00410
cytotoxicity
midline catheter failure
Equipment Failure
Female
medicine.symptom
business
medicine.drug
Subjects
Details
- Language :
- English
- ISSN :
- 15352900 and 10792082
- Volume :
- 77
- Issue :
- 16
- Database :
- OpenAIRE
- Journal :
- American Journal of Health-System Pharmacy: AJHP
- Accession number :
- edsair.doi.dedup.....2c25be538428a90dbe8f652c11315c7c