Comparison of a unidirectional panoramic 3D endoluminal interpretation technique to traditional 2D and bidirectional 3D interpretation techniques at CT colonography: preliminary observations
- Source :
- Clinical Radiology. 65:118-125
- Publication Year :
- 2010
- Publisher :
- Elsevier BV, 2010.
-
Abstract
- To compare the evaluation times and accuracy of unidirectional panoramic three-dimensional (3D) endoluminal interpretation to traditional two-dimensional (2D) and bidirectional 3D endoluminal techniques.Sixty-nine patients underwent computed tomography colonography (CTC) after bowel cleansing. Forty-five had no polyps and 24 had at least one polypor = 6 mm. Patients underwent same-day colonoscopy with segmental unblinding. Three experienced abdominal radiologists evaluated the data using one of three primary interpretation techniques: (1) 2D; (2) bidirectional 3D; (3) panoramic 3D. Mixed model analysis of variance and logistic regression for correlated data were used to compare techniques with respect to time and sensitivity and specificity.Mean evaluation times were 8.6, 14.6, and 12.1 min, for 2D, 3D, and panoramic, respectively. 2D was faster than either 3D technique (p0.0001), and the panoramic technique was faster than bidirectional 3D (p = 0.0139). The overall sensitivity of each technique per polyp and per patient was 68.4 and 76.7% for 2D, 78.9 and 93.3% for 3D; and 78.9 and 86.7% for panoramic 3D.2D interpretation was the fastest overall, the panoramic technique was significantly faster than the bidirectional with similar sensitivity and specificity. The sensitivity for a single reader was significantly lower using the 2D technique. Each reader should select the technique with which they are most successful.
- Subjects :
- Male
medicine.medical_specialty
Virtual colonoscopy
Colonic Polyps
Colonoscopy
Sensitivity and Specificity
Imaging, Three-Dimensional
Computed Tomography Colonography
Humans
Medicine
Radiology, Nuclear Medicine and imaging
Bowel cleansing
Aged
Retrospective Studies
Aged, 80 and over
Observer Variation
medicine.diagnostic_test
business.industry
General Medicine
Middle Aged
Reference Standards
Surgery
Radiographic Image Interpretation, Computer-Assisted
Female
business
Nuclear medicine
Colonography, Computed Tomographic
Subjects
Details
- ISSN :
- 00099260
- Volume :
- 65
- Database :
- OpenAIRE
- Journal :
- Clinical Radiology
- Accession number :
- edsair.doi.dedup.....2c9ec92c91241e82da34ceccae362ef7
- Full Text :
- https://doi.org/10.1016/j.crad.2009.11.001