Back to Search Start Over

Comparison of airborne radiation detectors carried by rotary-wing unmanned aerial systems

Authors :
S. Neumaier
U. Stöhlker
P. Royo
Arturo Vargas
D. Costa
E. Pastor
R. Luff
M. Macias
Maksym Luchkov
Universitat Politècnica de Catalunya. Institut de Tècniques Energètiques
Universitat Politècnica de Catalunya. Departament d'Arquitectura de Computadors
Universitat Politècnica de Catalunya. Doctorat en Enginyeria Nuclear i de les Radiacions Ionitzants
Universitat Politècnica de Catalunya. DRM - Dosimetria i Radiofísica Mèdica
Universitat Politècnica de Catalunya. ICARUS - Intelligent Communications and Avionics for Robust Unmanned Aerial Systems
Source :
UPCommons. Portal del coneixement obert de la UPC, Universitat Politècnica de Catalunya (UPC)
Publication Year :
2021
Publisher :
Elsevier BV, 2021.

Abstract

The Universitat Politecnica de Catalunya (UPC), the Physikalisch-Technische Bundesanstalt (PTB) and the German Federal Office of Radiation Protection (BfS) have analysed the response of a 2”x2” (diameter x height) NaI and a 1.5”x1.5” CeBr3 scintillators, and a 1500 mm3 CZT semiconductor airborne spectrometric detectors mounted on Unmanned Aerial Vehicles (UAV) in a comparison campaign carried out in the aerial site of Mollerussa (Spain). The background count rates and H*(10) rates measured by the airborne detectors at the aerial site and with a 137Cs point source of 345 MBq have been compared at altitudes of 1.5 m, 10 m, 20 m, 40 m, 60 m and 100 m a.g.l. (above ground level). Furthermore, natural activity concentrations in soil have been calculated with different methodologies using the spectra acquired in the background flights. The airborne detectors together with the implemented calculation methodologies show in general a good agreement. The CZT detector has a significant lower efficiency than both scintillators due to the smaller size and, therefore shows poorer results. Finally, parallel flights over the 137Cs point source at 10 m, 20 m and 40 m were carried to evaluate the methods implemented by the three teams to localize point sources. The three systems were able to locate properly the source. The project 16ENV04 “Metrology for mobile detection of ionising radiation following a nuclear or radiological incident” has received funding from the EMPIR programme co-financed by the participating states and from the European Union’s Horizon 2020 research and innovation programme.

Details

ISSN :
13504487
Volume :
145
Database :
OpenAIRE
Journal :
Radiation Measurements
Accession number :
edsair.doi.dedup.....2cfdd68f80a4319fe14da0341c9079c2
Full Text :
https://doi.org/10.1016/j.radmeas.2021.106595