Back to Search Start Over

Intravascular optical coherence tomography for the evaluation of arterial bifurcations covered by flow diverters

Authors :
Charbel Mounayer
Catherine Yardin
Christina Iosif
Pierre Carles
Eduardo Pedrolo Silveira
Eduardo Waihrich
Gilles Trolliard
Suzana Saleme
Sebastien Ponsonnard
Equipe de Recherche Médicale Appliquée (ERMA)
Université de Limoges (UNILIM)-CHU Limoges-Génomique, Environnement, Immunité, Santé, Thérapeutique (GEIST FR CNRS 3503)
Service de Neuroradiologie interventionnelle [CHU Limoges]
CHU Limoges
Science des Procédés Céramiques et de Traitements de Surface (SPCTS)
Institut des Procédés Appliqués aux Matériaux (IPAM)
Université de Limoges (UNILIM)-Université de Limoges (UNILIM)-Ecole Nationale Supérieure de Céramique Industrielle (ENSCI)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Université de Limoges (UNILIM)
Axe 3 : organisation structurale multiéchelle des matériaux (SPCTS-AXE3)
Université de Limoges (UNILIM)-Université de Limoges (UNILIM)-Ecole Nationale Supérieure de Céramique Industrielle (ENSCI)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Université de Limoges (UNILIM)-Institut des Procédés Appliqués aux Matériaux (IPAM)
Service d'Histologie, cytologie, cytogénétique, biologie cellulaire [CHU Limoges]
Service de Neurologie [CHU Limoges]
Source :
Journal of Neurointerventional Surgery, Journal of Neurointerventional Surgery, BMJ Journals, 2016, 8 (12), pp.1283-1287. ⟨10.1136/neurintsurg-2015-012084⟩
Publication Year :
2016
Publisher :
HAL CCSD, 2016.

Abstract

Background and objectiveDue to its high spatial resolution, intravascular optical coherence tomography (OCT) has been used as a valid method for in vivo evaluation of several types of coronary stents at straight lumen and bifurcation sites. We sought to evaluate its effectiveness for flow diverting stents deployed in arterial bifurcation sites involving jailing of a side branch.MethodsFour large white swine were stented with flow diverting stents covering the right common carotid artery–ascending pharyngeal artery bifurcation. After 12 weeks of follow-up the animals were evaluated by digital subtraction angiography and intravascular OCT and subsequently sacrificed. Neointimal thickness on the parent arteries and the free segments of the stent were measured. The stented arteries were harvested and underwent scanning electron microscopy (SEM) imaging. Ostia surface values were measured with OCT three-dimensional (3D) reconstructions and SEM images.ResultsAll endovascular procedures and OCT pullback runs were feasible. Stent apposition was satisfactory on the immediate post-stent OCT reconstructions. At 12-week controls, all stents and jailed branches were patent. Mean neointimal thickness was 0.11±0.04 mm on the free segments of the stent. The mean ostia surface at 12 weeks was 319 750±345 533 μm2 with 3D-OCT reconstructions and 351 198±396 355 μm2 with SEM image-derived calculations. Good correlation was found for ostia surface values between the two techniques; the values did not differ significantly in this preliminary study.ConclusionsIntravascular OCT appears to be a promising technique for immediate and follow-up assessment of the orifice of arterial branches covered by flow diverting stents.

Details

Language :
English
ISSN :
17598478 and 17598486
Database :
OpenAIRE
Journal :
Journal of Neurointerventional Surgery, Journal of Neurointerventional Surgery, BMJ Journals, 2016, 8 (12), pp.1283-1287. ⟨10.1136/neurintsurg-2015-012084⟩
Accession number :
edsair.doi.dedup.....2d58dbcaa35ad890b1373a2314b04e41
Full Text :
https://doi.org/10.1136/neurintsurg-2015-012084⟩