Mapping electrical properties heterogeneity of tumor using boundary informed electrical properties tomography (BIEPT) at 7T
- Source :
- Magnetic Resonance in Medicine. 81:393-409
- Publication Year :
- 2018
- Publisher :
- Wiley, 2018.
-
Abstract
- Purposes To develop and evaluate a boundary informed electrical properties tomography (BIEPT) technique for high-resolution imaging of tumor electrical properties (EPs) heterogeneity on a rodent tumor xenograft model. Methods Tumor EP distributions were inferred from a reference area external to the tumor, as well as internal EP spatial variations derived from a plurality of relative transmit B1 measurements at 7T. Edge sparsity constraint was enforced to enhance numerical stability. Phantom experiments were performed to determine the imaging accuracy and sensitivity for structures of various EP values, as well as geometrical sizes down to 1.5 mm. Numerical simulation of a realistic rodent model was used to quantify the algorithm performance in the presence of noise. Eleven athymic rats with human breast cancer xenograft were imaged in vivo, and representative pathological samples were acquired for comparison. Results Reconstructed EPs of the phantoms correspond well to the ground truth acquired from dielectric probe measurements, with the smallest structure reliably detectable being 3 mm. EPs heterogeneity inside a tumor is successfully retrieved in both simulated and experimental cases. In vivo tumor imaging results demonstrate similar local features and spatial patterns to anatomical MRI and pathological slides. The imaged conductivity of necrotic tissue is higher than that of viable tissues, which agrees with our expectation. Conclusion BIEPT enables robust detection of tumor EPs heterogeneity with high accuracy and sensitivity to small structures. The retrieved quantitative EPs reflect tumor pathological features (e.g., necrosis). These results provide strong rationale to further expand BIEPT studies toward pathological conditions where EPs may yield valuable, non-invasive biomarkers.
- Subjects :
- Materials science
Radio Waves
Normal Distribution
Boundary (topology)
Article
Imaging phantom
030218 nuclear medicine & medical imaging
Necrosis
03 medical and health sciences
0302 clinical medicine
In vivo
Biomarkers, Tumor
Animals
Humans
Computer Simulation
Radiology, Nuclear Medicine and imaging
Sensitivity (control systems)
Tomography
Tumor xenograft
Tumor imaging
Ground truth
Phantoms, Imaging
Electric Conductivity
Brain
Models, Theoretical
Magnetic Resonance Imaging
Rats
Female
Tomography, X-Ray Computed
Monte Carlo Method
Algorithms
Neoplasm Transplantation
Software
030217 neurology & neurosurgery
Biomedical engineering
Subjects
Details
- ISSN :
- 15222594 and 07403194
- Volume :
- 81
- Database :
- OpenAIRE
- Journal :
- Magnetic Resonance in Medicine
- Accession number :
- edsair.doi.dedup.....2d8c3275bc3afa0cc63e40eeae7ff8c1
- Full Text :
- https://doi.org/10.1002/mrm.27414