Back to Search Start Over

The MGPA electromagnetic calorimeter readout chip for CMS

Authors :
G. Hall
J. Crooks
Michel Raymond
M.J. French
Source :
Scopus-Elsevier
Publication Year :
2005
Publisher :
Institute of Electrical and Electronics Engineers (IEEE), 2005.

Abstract

The multiple-gain preamplifier (MGPA) is a three-gain channel 0.25 /spl mu/m CMOS chip matched to the noise and linearity requirements of the electromagnetic calorimeter for the Compact Muon Solenoid (CMS) experiment. A choice of external feedback components to the first-stage amplifier allows the chip to match the different full-scale signal and noise requirements for both barrel and end-cap regions of the detector. For the barrel (end-cap) application the noise is less than 10 000 (3,500) electrons at a peaking time of 40 ns and an integral nonlinearity of approximately /spl plusmn/0.1% full-scale is achieved for all three gain ranges. Details of the design and performance are presented, including measurements of nonlinearity, pulse-shape matching, noise, and radiation tolerance.

Details

ISSN :
00189499
Volume :
52
Database :
OpenAIRE
Journal :
IEEE Transactions on Nuclear Science
Accession number :
edsair.doi.dedup.....3247cf3abe1dae840859109d50447162
Full Text :
https://doi.org/10.1109/tns.2005.850979