Back to Search Start Over

Usefulness of Non-Magnifying Narrow-Band Imaging in Screening of Early Esophageal Squamous Cell Carcinoma: A Prospective Comparative Study Using Propensity Score Matching

Authors :
Kosei Hirakawa
Yasuaki Nagami
Tetsuo Arakawa
Hirohisa Machida
Satoshi Sugimori
Masami Nakatani
Kenji Watanabe
Naoshi Kubo
Natsuhiko Kameda
Hiroyoshi Iguchi
Masaichi Ohira
Kazunari Tominaga
Tetsuya Tanigawa
Masatsugu Shiba
Hirotoshi Okazaki
Yasuhiro Fujiwara
Hirokazu Yamagami
Toshio Watanabe
Source :
The American Journal of Gastroenterology
Publication Year :
2014
Publisher :
Ovid Technologies (Wolters Kluwer Health), 2014.

Abstract

OBJECTIVES: The usefulness of non-magnifying endoscopy with narrow-band imaging (NBI; NM-NBI) in the screening of early esophageal squamous cell carcinoma (SCC) and high-grade intraepithelial neoplasia (HGIN) remains unclear. Here, we aimed to compare NM-NBI and chromoendoscopy with iodine staining (CE-Iodine) in terms of the diagnostic performance, and to evaluate the usefulness of NM-NBI in detecting early esophageal SCC. METHODS: We prospectively enrolled 202 consecutive patients (male/female=180/22; median age, 67 years) with high-risk factors for esophageal SCC. All patients received endoscopic examination with NM-NBI and CE-Iodine to screen for early esophageal SCC or HGIN. We conducted the examinations sequentially, and calculated the accuracy, sensitivity, and specificity through a per-lesion-based analysis. A propensity score matching analysis was performed to reduce the effects of selection bias, and we compared the respective outcomes according to NM-NBI and CE-Iodine after matching. RESULTS: The accuracy, sensitivity, and specificity of NM-NBI were 77.0, 88.3, and 75.2%, respectively, and those for unstained areas by CE-Iodine were 68.0, 94.2, and 64.0, respectively. The accuracy and specificity of NM-NBI were superior to those of CE-Iodine (P=0.03 and P=0.01, respectively). However, the sensitivity did not significantly differ between NM-NBI and CE-Iodine (P=0.67). The accuracy and specificity of NM-NBI before matching were superior to those of CE-Iodine after matching (P=0.04 and P=0.03). CONCLUSIONS: NM-NBI was useful and reliable for the diagnosis of esophageal SCC and can be a promising screening strategy for early esophageal SCC.

Details

ISSN :
00029270
Volume :
109
Database :
OpenAIRE
Journal :
American Journal of Gastroenterology
Accession number :
edsair.doi.dedup.....34c123845b461fe1f9b4c9d8ce78f337
Full Text :
https://doi.org/10.1038/ajg.2014.94