Back to Search
Start Over
Relationship of Urethral Dose and Genitourinary Toxicity Among Patients Receiving Vaginal High Dose Rate Interstitial Brachytherapy
- Source :
- Clinical Oncology. 33:773-779
- Publication Year :
- 2021
- Publisher :
- Elsevier BV, 2021.
-
Abstract
- Aims Interstitial brachytherapy (ISBT) plays an important role in the management of locally advanced gynaecological malignancies. However, the relationship between urinary toxicity and dose to the urethra is not well understood. We sought to evaluate the correlation between urethral dose and the incidence of genitourinary complications among patients undergoing vaginal high dose rate ISBT. Materials and methods Eighty-three patients treated with ISBT between August 2014 and April 2018 were retrospectively reviewed. CTCAE version 5.0 was used to grade toxicity. Individual treatment plans were evaluated to collect dose parameters. Urethral contours were added to the structure sets using a uniform 1 cm diameter brush and minimum doses to the hottest 0.1, 0.2 and 0.5 cm3 (D0.1cm3, D0.2cm3 and D0.5cm3) of the urethra were obtained. Total (ISBT ± external beam radiotherapy) equivalent doses in 2 Gy fractions (EQD2) received by the targets and organs at risk were calculated. Numerical counts (%) and medians (interquartile range) were used to characterise the data. Fisher's exact and the Mann–Whitney–Wilcox tests were used as appropriate. Receiver operator curve analysis was used to define the urethral threshold dose that correlated to genitourinary toxicity. Results The median age and follow-up times were 67 years (59–75) and 25 months (16–37), respectively. Patients had predominantly primary endometrial (49%) and vaginal (37%) cancer, with four (5%) patients with metastatic rectal cancer to the vagina. Twenty-four of 79 (30%) patients experienced acute genitourinary toxicity and 34 of 71 (48%) experienced late genitourinary toxicity. In both analyses, the median urethral dose was significantly higher among those with toxicity. Receiver operator curve analysis indicated that D0.1cm3, D0.2cm3 and D0.5cm3 of the urethra were associated with the development of toxicity at doses >78, >71 and >62 Gy, respectively. Conclusion Urethral dose seems to predict genitourinary toxicity in ISBT of vaginal tumours. Further study with an expanded cohort and longer follow-up is warranted.
- Subjects :
- Male
medicine.medical_specialty
medicine.medical_treatment
Urinary system
Brachytherapy
Urology
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Urethra
Interquartile range
medicine
Humans
Radiology, Nuclear Medicine and imaging
External beam radiotherapy
Radiation Injuries
Retrospective Studies
Genitourinary system
business.industry
Radiotherapy Dosage
medicine.anatomical_structure
Oncology
030220 oncology & carcinogenesis
Vagina
Toxicity
Female
business
Subjects
Details
- ISSN :
- 09366555
- Volume :
- 33
- Database :
- OpenAIRE
- Journal :
- Clinical Oncology
- Accession number :
- edsair.doi.dedup.....3687bb38864bc6bfd09e2c1c9eba6c52
- Full Text :
- https://doi.org/10.1016/j.clon.2021.05.006