Back to Search
Start Over
Practical Immuno-PET Radiotracer Design Considerations for Human Immune Checkpoint Imaging
- Source :
- Journal of Nuclear Medicine. 58:538-546
- Publication Year :
- 2016
- Publisher :
- Society of Nuclear Medicine, 2016.
-
Abstract
- Immune checkpoint blockade has emerged as a promising cancer treatment paradigm. Unfortunately, there are still a large number of patients and malignancies that do not respond to therapy. A major barrier to validating biomarkers for the prediction and monitoring of responders to clinical checkpoint blockade has been the lack of imaging tools to accurately assess dynamic immune checkpoint expression. Here, we sought to optimize noninvasive immuno-PET imaging of human programmed death-ligand 1 (PD-L1) expression, in a preclinical model, using a small high-affinity engineered protein scaffold (HAC-PD1). Six HAC-PD1 radiotracer variants were developed and used in preclinical imaging and biodistribution studies to assess their ability to detect human PD-L1 expression in vivo. Radiotracer design modifications included chelate, glycosylation, and radiometal. HACA-PD1 was adopted as the naming convention for aglycosylated tracer variants. NOD scid γ-(NSG) mice were inoculated with subcutaneous tumors engineered to either be constitutively positive (CT26 hPD-L1) or be negative (ΔmPD-L1 CT26) for human PD-L1 expression. When the tumors had grown to an average size of 1 cm in diameter, mice were injected with 0.75–2.25 MBq (∼10 μg) of an engineered radiotracer variant and imaged. At 1 h after injection, organs were harvested for biodistribution. Of the practical immuno-PET tracer modifications considered, glycosylation was the most prominent design factor affecting tracer uptake, specificity, and clearance. In imaging studies, aglycosylated 64Cu-NOTA-HACA-PD1 most accurately visualized human PD-L1 expression in vivo. We reasoned that because of the scaffold’s small size (14 kDa), its pharmacokinetics may be suitable for labeling with the short-lived and widely clinically available radiometal 68Ga. At 1 h after injection, 68Ga-NOTA-HACA-PD1 and 68Ga-DOTA-HACA-PD1 exhibited promising target-to-background ratios in ex vivo biodistribution studies (12.3 and 15.2 tumor-to-muscle ratios, respectively). Notably, all HAC-PD1 radiotracer variants enabled much earlier detection of human PD-L1 expression (1 h after injection) than previously reported radiolabeled antibodies (>24 h after injection). This work provides a template for assessing immuno-PET tracer design parameters and supports the translation of small engineered protein radiotracers for imaging human immune checkpoints.
- Subjects :
- Models, Molecular
0301 basic medicine
Biodistribution
Pathology
medicine.medical_specialty
Glycosylation
Immunoconjugates
Protein Conformation
medicine.medical_treatment
Protein Engineering
B7-H1 Antigen
Heterocyclic Compounds, 1-Ring
Mice
03 medical and health sciences
0302 clinical medicine
Immune system
Cancer immunotherapy
In vivo
Cell Line, Tumor
PD-L1
medicine
Animals
Humans
Tissue Distribution
Radiology, Nuclear Medicine and imaging
Radioactive Tracers
biology
Chemistry
Immune checkpoint
Gene Expression Regulation, Neoplastic
030104 developmental biology
Copper Radioisotopes
Oncology
Drug Design
Positron-Emission Tomography
030220 oncology & carcinogenesis
biology.protein
Cancer research
Preclinical imaging
Ex vivo
Subjects
Details
- ISSN :
- 2159662X and 01615505
- Volume :
- 58
- Database :
- OpenAIRE
- Journal :
- Journal of Nuclear Medicine
- Accession number :
- edsair.doi.dedup.....37ddad0b9f1f72539df83d660e172cda
- Full Text :
- https://doi.org/10.2967/jnumed.116.177659